Operation, 7 status messages and diagnostic information – KROHNE MAC 100 EN User Manual
Page 66
6
OPERATION
66
OPTISENS MAC 100
www.krohne.com
04/2011 - MA OPTISENS MAC 100 R01 en
6.6.8 Passwords
You can activate passwords for different menu levels (function C5.6.4 and C5.6.5):
Password levels
Common usage
• Protection of the menus "Test" and "Setup" with a password, free access to the menu "Quick
setup". You can achieve this by activating a setup password only.
• Protection of the quick setup with a known password and confidential setup password to
protect the quick setup against arbitrary use and the setup and test menus against misuse.
This is done by activating a password for the menus "setup" and "quick setup".
6.7 Status messages and diagnostic information
Menu
Required password
Point of query
Preview of setting
possible
Quick setup
For quick setup
At entry to the
parameter edit mode
Yes
Test
For setup
Setup
For setup
Service
For service
At entry to the service
menu
No
INFORMATION!
If you activate a password for the menu "Quick setup" only and not for the menu "Setup", the
menus "Setup" and "Test" will also be protected by the quick setup password.
INFORMATION!
Note the following information concerning the tables with the status messages in the following
subsections:
•
The tables also contain messages related to HART, Profibus, Foundation Fieldbus and
RS485/Modbus devices; though this device features are currently not available but in
preparation.
•
The devices groups all error messages and maps them according to their category and
importance; the following subsections and their tables represent the categories and the
order of importance. You find a short description of the error category in the table below this
admonition.
•
On the display you recognize the error category with the help of the character in front of the
message (e.g. all failure messages start with a bold "F
FF
F"); these characters are independent of
the used language, they were individually defined by the manufacturer.
•
If messages of the category F
FF
F, F and S appear and the device is in the normal measuring
mode, a triangle in the header appears (this triangle does not appear if only information is
shown).
.book Page 66 Friday, April 1, 2011 4:59 PM