ERROR MESSAGE

ESR ERROR BIT SET

(SEE PAR. A.5)

EXPLANATION

0,“No error”

None

No error.

-100,“Command error”

Command Error bit 5

Command and data understood, but more informa-
tion included which is not recognized.

-102,”Syntax error”

Command Error bit 5

First 4 characters recognized, subsequent charac-
ters not recognized.

-103,”Invalid separator”

Command Error bit 5

For example, VOLT.PROT received instead of
VOLT:PROT.

-108,”Parameter Not Allowed Error”

Command Error bit 5

Volt12 sequence, channel number is invalid.

-109,”Missing parameter”

Command Error bit 5

For example, VOLT instead of VOLT 21.

-111,”Header separator error”

Command Error bit 5

Missing space between volt and value or ; missing.

-113,”Undefined header”

Command Error bit 5

First 4 characters could not be identified as legal
command.For example, command VLT instead of
VOLT.

-120,”Numeric data error”

Command Error bit 5

Expected number but other characters were
detected.

-121,”Invalid character in number”

Command Error bit 5

Volt 1,500 (comma not allowed).

-123,”Exponent too large”

Command Error bit 5

Exponent E+3 or greater is invalid.

-141,”Invalid character data”

Command Error bit 5

For example OUTP OFD or OUTP STOP instead of
OUTP OFF.

-150,”String data error”

Command Error bit 5

Invalid characters were detected in numeric entry.
For example E.1 instead of E+1 or 4d3 instead of
4.3.

-203,”Command protected”

Execution error bit 4

Command only valid in password Cenable state.

-221,”Settings conflict”

Execution error bit 4

Invalid password from syst:pass:cen command.

-222,“Data out of range”

Execution error bit 4

Value exceeds power supply rating.

-223,”Data format error”

Execution error bit 4

Multiple decimals in digit, Multiple E, etc.

-224,“Illegal parameter value”

Execution error bit 4

For example, OUTP 2 instead of OUTP 1.

-241,”Hardware missing”

Execution error bit 4

Requesting device 2 status (INST:NSEL 2).

-282,”Illegal program name”

Execution error bit 4

Executing prog:run without LIST:SEQ command.

-301,”Value bigger than limit”

Device Error bit 3

Requesting a time of 301 which is bigger than limit.

-311,”Memory error”

Device Error bit 3

Power-up NV RAM error.

-314,”Save/recall memory error”

Device Error bit 3

Using cell other than 1 - 41 for SAV and RCL.

-341,”Non Volatile Mem. CRC error”

Device Error bit 3

Power supply constants may be corrupted; recali-
bration may be necessary.

-350, “Queue overflow”

Query Error bit 2

More than 15 errors are in queue.

-410,”Query interrupted”

Query Error bit 2

New command sent before data from previous
query read. Previous query data lost.

-430, “Query Deadlocked”

Query Error bit 2

Over 255 characters received in single input string.