A.14 *sre? — service request enable query, A.15 *stb? — status byte register query, A.16 *trg — trigger command – KEPCO ATE-DMG SERIES User Manual
Page 69: A.17 *tst? — self test query, A.14, A.15, A.16, A.17, E a-3, Le a-3), the req
ATE-DMG 042314
A-5/(A-6 Blank)
A.14
*SRE? — SERVICE REQUEST ENABLE QUERY
*SRE?
Syntax:
*SRE?
Response:
Description: Reads the Service Enable Register. Used to determine which events of the Status Byte Register are
programmed to cause the power supply to generate a service request (1 = set = function enabled, 0 =
reset = function disabled). Related Commands: *SRE, *STB? (See example, Figure A-1.)
A.15
*STB? — STATUS BYTE REGISTER QUERY
*STB?
Syntax:
*STB?
Response:
Description: Reads Status Byte Register without clearing it. This Query reads the Status Byte Register (bit 6 =
MSS) without clearing it (1 = set = function enabled, 0 = reset = function disabled). The register is
cleared only when subsequent action clears all set bits. MSS is set when the power supply has one
ore more reasons for requesting service. (A serial poll also reads the Status Byte Register, except that
bit 6 = RQS, not MSS; and RQS will be reset.) Related Commands: *SRE, *SRE?. (See example, Fig-
ure A-1.)
A.16
*TRG — TRIGGER COMMAND
*TRG
Syntax:
*TRG
Description: Triggers the power supply to be commanded to preprogrammed values of output current and
voltage. When the trigger is armed (checked by examining WTG bit in Status Operational Condition
register) *TRG generates a trigger signal. The trigger will change the output of the power supply to the
output voltage and current levels specified by VOLT:TRIG and CURR:TRIG commands and clear the
WTG bit in the Status Operation
Condition register. If INIT:CONT has been issued, the trigger
subsystem is immediately rearmed for subsequent triggers, and the WTG bit is again set to
1. *TRG or GET are both addressed commands (only devices selected as listeners will exe-
cute the command).
Related Commands:
ABOR, INIT, TRIG, CURR:TRIG, VOLT:TRIG.
(See
example, Figure A-1.
)
A.17
*TST? — SELF TEST QUERY
*TST?
Syntax:
*TST?
Returned value: 0 or 1 (0 = pass test, 1 = fail test)
Description:
Power Supply test.This query causes the power supply to do a self test and provide the controller
with pass/fail results. A cyclic redundancy check (CRC) is performed on non-volatile RAM. A “1” is
returned if there is an error.
TABLE A-3. SERVICE REQUEST ENABLE AND STATUS BYTE REGISTER BITS
CONDITION
OPER
MSS
RQS
ESB
MAV
QUES
ERR
QUE
NU
NU
BIT
7
6
5
4
3
2
1
0
VALUE
128
64
32
16
8
4
2
1
OPER Operation
Status
Summary
MSS
Master Status Summary
RQS
Request for Service
ESB
Event Status Byte summary
MAV
Message available
QUES
QUEStionable Status Summary
ERR QUE
1 or more errors occurred (see
PAR. B.84)
NU
(Not Used)