B.20 initiate[:immediate] command, B.21 initiate:continuous command, B.22 initiate:continuous query – KEPCO ATE-DMG SERIES User Manual
Page 77: B.23 instrument:state command, B.24 list:current command, B.25 [sour:]list:current? query, B.20, B.21, B.22, B.23

ATE-DMG 042314
B-7
B.20
INITiate[:IMMediate]
COMMAND
INIT[:IMM]
Syntax:
Short Form: INIT:[IMM] Long Form: INITiate[:IMMediate]
Description: Enables a single trigger. If INIT:CONT is OFF, then INIT[:IMM] arms the trigger system for a single
trigger. If INIT:CONT is ON, then the trigger system is continuously armed and INIT[:IMM] is redun-
dant. This command enables a single trigger. A GPIB
sequence. Upon receipt of the
grammed values of voltage and current established by the VOLT:TRIG and CURR:TRIG commands.
After a GPIB
mands have no effect unless preceded by INIT or INIT:CONT ON. Related Commands:
*TRG. (See example, Figure B-1.)
B.21
INITiate:CONTinuous COMMAND
INIT:CONT
Syntax:
Short Form: INIT:CONT {ON | OFF} or {1 | 0} (1 = on, 0 = off)
Long Form: INITiate:CONTinuous {ON | OFF} or {1 | 0} (1 = on, 0 = off)
Description: INIT:CONT ON enables continuous triggers.; INIT:CONT OFF disables continuous triggers. If
INIT:CONT is OFF, then INIT[:IMM] arms the trigger system for a single trigger. If INIT:CONT is ON,
then the trigger system is continuously armed and INIT[:IMM] is redundant. Executing *RST command
sets INIT:CONT to OFF. (See example, Figure B-1.)
B.22
INITiate:CONTinuous
QUERY
INIT:CONT?
Syntax:
Short Form: INIT:CONT?
Long Form: INITiate:CONTinuous?
Return Value: 1 or 0
Description: Determines whether continuous triggers are enabled or disabled. Power supply returns value of
INIT:CONT flag: “1” = continuous triggers are enabled (INIT:CONT ON); “0” = continuous triggers dis-
abled (INIT:CONT OFF). (See example, Figure B-1.)
B.23
INSTrument:STATe COMMAND
INST:STAT
Syntax:
Short Form: INST:STAT
Long Form: INSTrument:STATe
Description: Operation is identical to OUTPut:STATe command (PAR. B.42) and is provided for compatibility with
other vendors products.
B.24
LIST:CURRent COMMAND
LIST:CURR
Syntax:
Short Form: LIST:CURR[:LEV]
Long Form: LIST:CURRent[:LEVel]
Description: Sets the current (Amps) value for the memory location selected by LIST:IND. If the value is out of
the acceptable current range for the power supply model, an error message: -222,”Data out of range”
is posted in the output queue. The current value is stored in non-volatile memory and is retained when
the power supply is turned off. Related Commands: LIST:IND. LIST:IND?, LIST:CURR?. (See exam-
ple, Figure B-4.)
B.25
[SOUR:]LIST:CURRent?
QUERY
LIST:CURR?
Syntax:
Short Form: LIST:CURR[:LEV]?
Long Form: LIST:CURRent[:LEVel]?
Return Value:
Description: Returns current value (Amps) stored in indexed memory location selected by LIST:IND. Related
Commands: LIST:IND. LIST:IND?, LIST:CURR. (See example, Figure B-4.)