beautypg.com

B.26 [sour:]list:current:protect command, Figure b-4. using list commands and queries, B.27 [sour:]list:current:protect? query – KEPCO ATE-DMG SERIES User Manual

Page 78: B.28 [sour:]list:dwell command, B.26, B.27, B.28, List:curr:prot, List:dwel

background image

B-8

ATE-DMG 042314

B.26

[SOUR:]LIST:CURRent:PROTect COMMAND

LIST:CURR:PROT

Syntax:

Short Form: LIST:CURR:PROT Long Form: LIST:CURRent:PROTect
= digits with decimal point and Exponent

Description: Sets the current protection (Amps) value for the memory location selected by LIST:IND. If the

value is out of the acceptable current range for the power supply model, an error message: -222,”Data
out of range” is posted in the output queue. The current value is stored in non-volatile memory and is
retained when the power supply is turned off. Related Commands: LIST:IND. LIST:IND?,
LIST:CURR:PROT?. (See example, Figure B-4.)

FIGURE B-4. USING LIST COMMANDS AND QUERIES

B.27

[SOUR:]LIST:CURRent:PROTect?

QUERY

LIST:CURR:PROT?

Syntax:

Short Form: LIST:CURR[:LEV]?

Long Form: LIST:CURRent[:LEVel]?

Return Value: = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1

Description: Returns current protection value (Amps) stored in indexed memory location selected by

LIST:IND. Related Commands: LIST:IND. LIST:IND?, LIST:CURR. (See example, Figure B-4.)

B.28

[SOUR:]LIST:DWELl COMMAND

LIST:DWEL

Syntax:

Short Form: LIST:DWEL (0.01 to 300)

Long Form: LIST:DWELl (0.01 to 300)

Description: Determines the execution time duration during a programmed sequence for the memory loca-

tion selected by LIST:IND. Sets time value (from 0.01 to 300) in seconds for memory location
selected by LIST:IND. A value of 0 means that this memory location will be skipped during the RUN
command (LOCal mode). The time value is stored in non-volatile memory and is retained when the
power supply is turned off. Related Commands: LIST:IND. LIST:IND?, LIST:DWEL?, LIST:SEQ. (See
example, Figure B-4.)

LIST:IND 21

Selects memory location 21.

LIST:IND?

Returns 21.

LIST:CURR 2.35E-1

Sets output current value of memory location 21 to 0.235A.

LIST:CURR?

Returns 2.35E-1.

LIST:CURR:PROT 0.67E+1

Sets current protection value of memory location 21 to 6.7A.

LIST:CURR:PROT?

Returns 0.67E+1.

LIST:VOLT:PROT 2.77E+1

Sets voltage protection value of memory location 21 to 27.7V.

LIST:VOLT:PROT?

Returns 2.77E+1.

LIST:DWEL 0.6

Sets memory location 21 time value to 0.6 second. During program
execution, after parameters specified by memory location 21 have
been applied for 0.6 second, power supply will switch to parameters
specified by memory location 21 sequence number.

LIST:SEQ:NEXT 39

Sets memory location sequence number to 39. During program
execution, when memory location 21 is complete, the next location
to be executed will be 39.

LIST:SEQ:NEXT?

Returns 39.

LIST:IND 22

Selects memory location 22.

LIST:IND?

Returns 22.

LIST:VOLT 1.256E+2

Sets output voltage value of memory location 22 to 125.6V.

LIST:VOLT?

Returns 1.256E+2.

LIST:SEQ:STAR 21

Sets memory location 21 as the starting location for executing a
program.

LIST:SEQ:STAR?

Returns 21.