Post process settings – Spectra Precision Survey Pro CE v3.60 GPS User Manual User Manual
Page 106
Job Menu
11
Post Process Settings
-RE 6HWWLQJV 3RVW 3URFHVV
The Post Process card is used to configure the post processing raw
data storage settings.
Recording Interval
: is where you set the
period for receiver internal raw data
recording. Set it to
Off
to disable post
processing data collection in survey pro
and to turn off receiver recording on
configuration.
RTK Autonomous Points:
is where you
specify action to take when accepting
autonomous points during RTK data
collection.
•
Do not store
: this option will prohibit acceptance of
autonomous points in RTK data collection routines.
•
Prompt for layer
: this option will prompt the user whenever
an autonomous point is accepted. The layer specified will be
the default layer to store autonomous points, but the user can
over ride at the prompt.
•
Store on selected layer
: this option will automatically store
autonomous points accepted during RTK data collection
routines on the specified layer.
Layer
: displays the layer selected to store autonomous points.
Select Layer
: opens up a layer prompt to allow you to select an
existing layer or create a new layer to store autonomous points.
Session Monitor
: is where you select to use monitoring of post
processing status for the session screen. To have Survey Pro display
warnings during post processing data collection, check
Warn me if
,
and specify threshold values for the number of
SV
,
HDOP
and
memory
.