Level – Hired-Hand System 2001 Power Curtain Controller User Manual
Page 39

4801-1200 System 2001 Power Curtain Controller
36
15.3 Blank Layout and Program Guide
Fill in the blanks with information for your setup
Draw in equipment on diagram below
All temperatures in degrees Fahrenheit. Target Temp _____ Degrees
Stages Equipment
Mode
Sensors
Offset Differential Timer
Min.
Vent
1
2
3
4
5
6
7
8
1. Begin with the Timer Setup Menu.-------------------------------------------------------------------------------
A. How many timers? .........................................................................................................................
B. What is your Timer Period? ...........................................................................................................
C. What is your Timer Percentage? ....................................................................................................
D. Do you prefer Normal or Expanded timers? ...................................................................................
E. What is your variable High and Low Temperature? ........................................................................
F. What is your variable High and Low Percentage? ...........................................................................
G. Timer 2, what Type would you like Timer 2 to operate as?.............................................................
H. What is the runtime for Timer Two? ..............................................................................................
2. Do you wish to use Min. Vent? -----------------------------------------------------------------------------------
A. If yes, which Unit?.........................................................................................................................
3. Now, program the 8 Stages. ---------------------------------------------------------------------------------------
A. Which Mode would you like to select? ...........................................................................................
B. Which of the sensor(s) would you like to operate Stage 1?..............................................................
C. What is the Offset? ........................................................................................................................
D. What is the Differential?................................................................................................................
E. Would you like this stage to be on a timer?.....................................................................................
F. What is your position of Min. Vent? ...............................................................................................
4. Now, we will Setup The System. ---------------------------------------------------------------------------------
A. Sensors For Display .......................................................................................................................
B. What is the combination for Unit 1?...............................................................................................
C. What is the combination for Unit 2?...............................................................................................
D. Do you wish for Auto Kill Fans to be engaged, yes or no?..............................................................
Level ____