4801-1200 System 2001 Power Curtain Controller

32

15.1 Level 1 Layout and Program Example

See below drawing for equipment layout.

S3

S2

S1

H1

H2

H3

H4

H5

H6

F1

F2

F3

F4

F5-8

F9-12

PT1

PT2

All temperatures in degrees Fahrenheit. Target Temp 90 Degrees

Stages Equipment

Mode

Sensors

Offset Differential Timer

Min.
Vent

1

H1-H4

Heat

1&2

2

2

No

2

H5, H6

Heat

3

30

2

No

3

F1, F2

CN

1&2

1

2

Yes

No

4

F3, F4

CN

3

30

30

No

5

F5, F9

CT

1, 2, & 3

30

30

No

6

F6, F10

CT

1, 2, & 3

30

30

No

7

F7, F11

CT

1, 2, & 3

30

30

No

8

F8, F12

CT

1, 2, & 3

30

30

No


1. Begin with the Timer Setup Menu.------------------------------------------------------------------------------- Answers
A. How many timers? ......................................................................................................................... 1
B. What is your Timer Period? ........................................................................................................... 10
C. What is your Timer Percentage? .................................................................................................... 6
D. Do you prefer Normal or Expanded timers? ................................................................................... Normal
E. What is your variable High and Low Temperature? ........................................................................
F. What is your variable High and Low Percentage? ...........................................................................
G. Timer 2, what Type would you like Timer 2 to operate as?.............................................................
H. What is the runtime for Timer Two? ..............................................................................................
2. Do you wish to use Min. Vent? ----------------------------------------------------------------------------------- No
A. If yes, which Unit?.........................................................................................................................
3. Now, program the 8 Stages. --------------------------------------------------------------------------------------- Yes
A. Which Mode would you like to select? ........................................................................................... Heat
B. Which of the sensor(s) would you like to operate Stage 1?.............................................................. 1 & 2
C. What is the Offset? ........................................................................................................................ 2
D. What is the Differential?................................................................................................................ 2
E. Would you like this stage to be on a timer?..................................................................................... No
F. What is your position of Min. Vent? ...............................................................................................
4. Now, we will Setup The System. ---------------------------------------------------------------------------------
A. Sensors For Display ....................................................................................................................... 1&2
B. What is the combination for Unit 1?............................................................................................... 1&2
C. What is the combination for Unit 2?............................................................................................... 1&2
D. Do you wish for Auto Kill Fans to be engaged, yes or no?.............................................................. Yes
E. Do you wish for Kill Fans on Cool Delay to be engaged, yes or no?................................................ No

Level 1