32
15.1 Level 1 Layout and Program Example
See below drawing for equipment layout.
S3
S2
S1
H1
H2
H3
H4
H5
H6
F1
F2
F3
F4
F5-8
F9-12
PT1
PT2
All temperatures in degrees Fahrenheit. Target Temp 90 Degrees
Stages Equipment
Mode
Sensors
Offset Differential Timer
Min.
Vent
1
H1-H4
Heat
1&2
2
2
No
2
H5, H6
Heat
3
30
2
No
3
F1, F2
CN
1&2
1
2
Yes
No
4
F3, F4
CN
3
30
30
No
5
F5, F9
CT
1, 2, & 3
30
30
No
6
F6, F10
CT
1, 2, & 3
30
30
No
7
F7, F11
CT
1, 2, & 3
30
30
No
8
F8, F12
CT
1, 2, & 3
30
30
No
1. Begin with the Timer Setup Menu.------------------------------------------------------------------------------- Answers
A. How many timers? ......................................................................................................................... 1
B. What is your Timer Period? ........................................................................................................... 10
C. What is your Timer Percentage? .................................................................................................... 6
D. Do you prefer Normal or Expanded timers? ................................................................................... Normal
E. What is your variable High and Low Temperature? ........................................................................
F. What is your variable High and Low Percentage? ...........................................................................
G. Timer 2, what Type would you like Timer 2 to operate as?.............................................................
H. What is the runtime for Timer Two? ..............................................................................................
2. Do you wish to use Min. Vent? ----------------------------------------------------------------------------------- No
A. If yes, which Unit?.........................................................................................................................
3. Now, program the 8 Stages. --------------------------------------------------------------------------------------- Yes
A. Which Mode would you like to select? ........................................................................................... Heat
B. Which of the sensor(s) would you like to operate Stage 1?.............................................................. 1 & 2
C. What is the Offset? ........................................................................................................................ 2
D. What is the Differential?................................................................................................................ 2
E. Would you like this stage to be on a timer?..................................................................................... No
F. What is your position of Min. Vent? ...............................................................................................
4. Now, we will Setup The System. ---------------------------------------------------------------------------------
A. Sensors For Display ....................................................................................................................... 1&2
B. What is the combination for Unit 1?............................................................................................... 1&2
C. What is the combination for Unit 2?............................................................................................... 1&2
D. Do you wish for Auto Kill Fans to be engaged, yes or no?.............................................................. Yes
E. Do you wish for Kill Fans on Cool Delay to be engaged, yes or no?................................................ No
Level 1