Program examples – Hired-Hand System 2001 Power Curtain Controller User Manual
Page 34

4801-1200 System 2001 Power Curtain Controller
31
Resistance
(K ohms)
Temp (F)
Temp (C)
Resistance
(Kohms)
Temp (F)
Temp (C)
5.326
104.0
40.0
4.454
112.1
44.5
5.262
104.5
40.3
4.402
112.6
44.8
5.199
105.1
40.6
4.334
113.4
45.2
5.137
105.6
40.9
4.284
113.9
45.5
5.076
106.2
41.2
4.217
114.6
45.9
4.995
106.9
41.6
4.168
115.2
46.2
4.936
107.4
41.9
4.120
115.7
46.5
4.877
108.0
42.2
4.057
116.4
46.9
4.820
108.5
42.5
3.995
117.1
47.3
4.763
109.0
42.8
3.949
117.7
47.6
4.688
109.8
43.2
3.888
118.4
48.0
4.633
110.3
43.5
3.844
118.9
48.3
4.579
110.8
43.8
3.785
119.7
48.7
4.507
111.6
44.2
All resistance values given in Kohms.
15. Program Examples
The following section contains two sample levels. Level one shows a house set up for half house brooding. Level two
shows the same house at the first transition from half house to full house operation. Following that example you will
find a blank level sheet that you can use to fill in data from your own house.
- Polar Cool: Portable Evaporative Cooling System (22 pages)
- Polar Cool: External Control Box (4 pages)
- Polar Cool: Pump & Float Replacement (2 pages)
- Polar Cool: PUMP REPLACEMENT (4 pages)
- Polar Cool: Wall Mount Kit (4 pages)
- Unitized Mega Cool (68 pages)
- Unitized Mega Cool: Square Bottom (63 pages)
- Mega-Cool: Square Reservoir (24 pages)
- Mega-Cool rev 6-09 (46 pages)
- Mega-Cool: Mega-Cool Pad Extender Kit (5 pages)
- Mega-Cool: Float Valve Replacement (1 page)
- Mega-Cool: Float Valve (Topaz) Replacement (1 page)
- Mega-Cool: In-Line Pump Motor Replacement (2 pages)
- Var-O-Matic (2 pages)
- System 1000 Power Vent (13 pages)
- System 1000 Power Vent (31 pages)
- System 500 Programs (Conventional Model) (5 pages)
- System 100 Variable Speed Controller (7 pages)
- System 500 Programs (Tunnel Model) (7 pages)
- System 1000 Power Curtain (17 pages)
- System 2000 AUTO TEMP (10 pages)
- System 500 Power Curtain Controller (31 pages)
- System 1000 Power Curtain Eight Stage Controller (34 pages)
- ICS-500 Environmental Controller (34 pages)
- Pressure Transducer Changeout (1 page)
- HH Software: HH.Net Router/Repeater (8 pages)
- HH Software: 900SS Wireless Network (10 pages)
- HH Software: Farm Manager (22 pages)
- HH Software: Data Shuttle Launch Pad (25 pages)
- Sens-O-Matic (Feed Hopper Switch) (2 pages)
- Manual Light Dimmer (2 pages)
- Electro Mechanical Controls (Relay-Switches): PHOTOHELIC POWER VENT (10 pages)
- Electro Mechanical Controls (Relay-Switches): PT Controller (9 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with DIF (6 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with Timer Override (7 pages)
- Electro Mechanical Controls (Relay-Switches): Photohelic Gauge (1 page)
- Feed Management System (15 pages)
- Contactor Control System (CCS): 4, 8, or 12 Stage (19 pages)
- Contactor Control System (CCS): Triple Pole 16-Stage (7 pages)
- Contactor Control System (CCS): Vent Machine Override 3 Wire PowerTrak (1 page)
- Evolution 4000 Control System (86 pages)
- Evolution Series 1200: Variable Output With Override Pot (14 pages)
- Evolution Series 1200: Variable Output (12 pages)
- Evolution Series 1200 (64 pages)