Hired-Hand Mega-Cool rev 4-08 User Manual
Page 7
Part No. 4801-5093 Rev 4-08
Unitized System
Page 7
Installation Cross-Section
(Agricultural Applications)
1.
Drawing shown to the left is an overview of a
completed Unitized system without end caps.
2.
The figure details the overall dimension for each pad
system and minimum clearance from roof.
NOTE: 2
″x 6″ refer to U. S. finished lumber
measurements.
6" Pad
"A"
"B"
4ft High Pad
61 1/8 in.
155.26 cm
66 in.
167.6 cm
5ft High Pad
73 1/8 in.
185.74 cm
78 in.
198.1 cm
6ft High Pad
85 1/8 in.
216.22 cm
90 in.
228.6 cm
4" Pad
"A"
"B"
4ft High Pad
62 1/8 in.
157.80 cm
66 in.
167.6 cm
5ft High Pad
74 1/8 in.
188.28 cm
78 in.
198.1 cm
6ft High Pad
86 1/8in.
218.76 cm
90 in.
228.6 cm
18” Min.
(45.7 cm)
3/8”
(.95 cm)
Side View
Cover
(Ordered Separately)
4.0 in.
(10.2 cm)
Splash Guard
Drip Rail
8” Pipe
Support Bracket
Curtain
Pad Cover
Splash Guard
Support Brkt.
Bottom Flashing
Overhang
Bracket
10.5 in.
(26.7 cm)
6.25”
(15.9 cm)
9.5” Min.
(24.1 cm)
8.5”
(21.6 cm)
8.0 in.
Min. Clearance
(20.3 cm)
"A"
See
Table
Pad
Height
"B"
See Table
Pad
(End-Cap
not shown)
Back-plate
Support Brkt.
Back-plate
2” x 6” Board or Steel Equivalent
(Optional) See Page 9