Part No. 4801-5093 Rev 4-08
Unitized System
Page 56
Detail F – Left Limit Switch Roller
Detail G – Manually Open Curtain
Limit
Switch
Roller
5. When the three switch grooves [21] are in line, the three Adjusting Screws in the
adjusting rings [9, 11, 13] are also in one line. Tighten the screws in the setting rings
[9, 11, 13] using a 1.5 mm hex wrench. Torque to 1.3 to 1.5 in.-lb.
6. Open the Curtain. See Detail G.
7. Turn the 3 Setting Rings of the Right Limit Switch like in Step 4.
8. Tighten screws in setting rings [15, 17, 19] to 1.3 to 1.5 in.-lb.
9. Verify the operation of the Limit Switch Settings by operating the curtain from the
controller.
10. Replace the tools in the Vinyl Seal and replace the Limit Switch Cover [6] and Seal [30].
Setting
Rings
Hex
Adjusting
Screws
Curtain Opens