NOTE: Install motor mount after drive pipe has been positioned in guide brackets.
1. Attach (2) mounting bracket braces to sides of mounting bracket with #14x1 Tek screws.
2. Attach mounting bracket assembly to fasten motor mount to mounting bracket with 3/8-16x1” screws and 3/8-16
lock nuts provided.
3. Position top edge of motor mount bracket exactly 19/32” (1.51 cm) from top edge of backplate.
4. Align slot of motor mount bracket in line with end of drive pipe.
IMPORTANT! Make sure that sprocket of motor will align exactly with the sprocket on end of drive pipe.
5. With motor mount properly aligned according to steps 1 and 2, attach to framing with 3/8x2” Lag Screws
Mounting
Bracket
Lock Motor
Assembly
Motor
Bracket
Drive Shaft
Assembly
Motor
Bracket
Mounting
Bracket
Top of
Mounting
Bracket
11/16"
(1.75 cm)
Mounting
Bracket
Brace
Lock Motor Mount
26”
(66.04 cm)
IMPORTANT! Diagram above shows two separate unitized systems with motor mounted between
systems. When two systems are installed, separate backplates by 2’-2” (66.04 cm) to allow for
installation of motor.
4 13/16”
(9.68cm)