Tr o u b l e s h o o t i n g C h a r t

• Press the HOME key for 2 seconds.
• Or, repeatedly press the ENTER key

to exit and return to the normal
operating mode.

Operator error.

Operator cannot get out of

Configuration Mode or
Menu Programming
Mode.

• Refer to Troubleshooting section on

Error Messages.

• Confirm that compatible sensors are

used in the system. Refer to con-
troller specifications.

• Check system wiring.
• Check system sensors.
• Confirm that a maximum of 1

grounded thermocouple is used in
the system.

• Confirm that compatible thermocou-

ple wires/extension wires are used
in the system.

• Verify that the programmed thermo-

couple curve matches the sensor
specification (see [tc```] parame-
ter setting.

• Verify that the programmed RTD

curve matches the sensor specifica-
tion (see [Rtd``] parameter set-
ting)

• Use WatHelp Diagnostics parameter

[tENP1] and [tENP2] to confirm
actual temperatures sensed on
channel 1 and 2.

Malfunctioning temperature sensors.
• [OFSt1] or [OFSt2] parameter

may be set incorrectly.

• System may have two grounded

thermocouple sensors, causing
ground loops.

• Loose or improper connections.
• Reversed sensor lead-wires.
• Sensor not compatible with control.
• Control not programmed properly.

Inaccurate temperatures

Set the [A_Loc] parameter to

[```no].

Application Number Security has

been set.

Software Application

Number cannot be
changed.

Set the [Loc``] parameter to

[```no].

Menu Program Security has been set.

Operator cannot reprogram

Menus.

To secure the Application Number, set

the [A_Loc] parameter to
[``YES].

Application Number Security has not

been set.

Software Application

Numbers are being
changed or tampered
with.

To secure the Menu programs, set the

[Loc``] parameter to [``YES].

Menu Program Security has not been

set.

Programmed Menus are

being changed or tam-
pered with.

• Refer to programming guide to reset

the time of day.

• If problem persists, return to factory.

• Real-time Clock is not programmed

properly.

• Battery is low.

Time of day is inaccurate

Possible Solutions

Possible Causes

Symptom/Indication

4 2

Wa t l o w M

I N I

C

H E F

2 0 0 0

H a r d w a r e & S o f t w a r e S e t u p G u i d e