S t e p 2 W i r e t h e C o n t r o l l e r

1 6

Wa t l o w M

I N I

C

H E F

2 0 0 0

H a r d w a r e & S o f t w a r e S e t u p G u i d e

Event Output 1 and Event Output 2

Note: The following illustrations are views of the back of the controller, not of the mating connector.

F 2 _ _ - _ _ _ 1 - _ _ _ _ (switched dc, 5V nominal, 30mA, non-isolated outputs)

Figure 16a — Event Outputs.

ç

Warning: If event outputs 1 & 2 are used to cause or initiate machine motion, appropriate reasonable care should be

taken to prevent personal injury or machine damage as a result of machine motion.

Note: Not all software applications require event outputs 1 & 2. For specific information consult the application

guide for the application you are using.

Output 5: Audible Alarm Output Signal Option

Note: The following illustrations are views of the back of the controller, not of the mating connector.

Alarm signal available at connector, 5V nominal, 30ma, non-isolated.

F 2 _ _ - _ _ _ _ - _ 0 _ _ (unit without internal audible alarm)

Figure 16c — Switched DC.

Note: Pin 5 is shared with event output 2 wiring.

1

2

3

4

5

6

7

8

9

5

9

10

11

12

13

14

15

Ext. Load

1

4

5

6

7

8

9

10

11

12

13

14

15

Ext. Load

3

2

Event Output 2

5

6

1

4

5

6

7

8

9

10

11

12

13

14

15

Ext. Load

3

2

Event Output 1

3

2