Step 4 program the menus, Program mode quick reference – Watlow MINICHEF 2000 User Manual
Page 26
H a r d w a r e & S o f t w a r e S e t u p G u i d e
Wa t l o w M
I N I
C
H E F
2 0 0 0
■
2 5
Step 4 Program the Menus
Program Mode Quick Reference
These are the functions, parameters and values that may be included in the Program
Mode. Not all parameters will appear. Different parameters are relevant in different
application numbers. For a detailed explanation, see the Appendix in this guide.
Function
Parameter
Value/Description
Your Settings
[M`__]
Menu Numbers XX
[Stpt1] Set point 1
Temp range low - temp range high
Temperature of set point 1.
[TiNe1] Time 1
Format varies based
Run time of set point 1.
on configuration.
[fan`1] Fan 1 Speed
Single Speed: [```on], [``Off]
Speed of fan 1 during time 1
Two Speed: [``Off], [```Lo],
[`HigH]
[Stpt2] Set point 2
Temp range low - temp range high
Temperature of set point 2.
[TiNe2] Time 2
Format varies based
Run time of set point 2.
on configuration.
[fan`2] Fan 2
Single Speed: [```on], [``Off]
Speed of fan during time 2
Two Speed: [``Off], [```Lo],
[`HigH]
[Probe] Probe
[```on], [``Off]
Activates probe function.
[ptenp] Probe Temperature
Temp range low - temp range high
Temperature at which probe
will switch controller to
hold condition.
[Stpt3] Set point 3
Temp range low - temp range high
Temperature of set point 3.
[TiNe3] Time 3
Format varies based
Run time of set point 3.
on configuration.
.
[fan`3] Fan 3 Speed
Single Speed: [```on], [``Off]
Speed of fan 3 during time 3
Two Speed: [``Off], [```Lo],
[`HigH]
[Stpt4] Set point 4
Temp range low - temp range high
Temperature of set point 4.
[TiNe4] Time 4
Format varies based
Run time of set point 4.
on configuration.
[fan`4] Fan 4
Single Speed: [```on], [``Off]
Speed of fan during time 4
Two Speed: [``Off], [```Lo],
[`HigH]
S t e p 4 P r o g r a m t h e M e n u s