S t e p 3 C o n f i g u r e t h e C o n t r o l l e r
2 4
■
Wa t l o w M
I N I
C
H E F
2 0 0 0
H a r d w a r e & S o f t w a r e S e t u p G u i d e
Note: When you are configuring your controller, always edit
[
Etype] and set the application number first (for
example,
[
appl`]
[
```20]). The parameters that follow are based on it. In general, parameters that appear ear-
lier on the list can influence the parameters and values that follow.
6. To change a value: press the Down-arrow key or the Up-arrow key.
7. To save the new value, which is on the display, press the Enter key. You will return
to the parameter list and the new value will flash to confirm that it has been
accepted.
If you do not want to enter the new value, press the Escape key. You will return to
the parameter list without making the change.
8. Repeat 4 through 7 until all values for this application have been programmed.
9. To leave the parameter list, press the Enter key. You will move to the function list.
10. Repeat 2 through 9 until the Equipment-Type, Setup and Thermal functions have
all been programmed. (The Diagnostics function is used for troubleshooting and is
read-only. No programming required.)
11. To leave the function list and exit the Configuration Mode, press the Enter key
twice.
Note: You can also exit the Program Mode from the parameter list or function list by pressing the Home key for two
seconds or by pressing the Enter key repeatedly.