beautypg.com

Ltssm, Setting – Teledyne LeCroy Voyager Exerciser Generation Script Language Manual User Manual

Page 160

background image

Teledyne LeCroy

Voyager USB 3.0 Exerciser Generation Script Language Reference Manual

151

Bit Location

Register Description

Attributes

This bit will be cleared automatically when the INF bit is not
set and the Count value is reached down to zero.

1

INF
0: Run the command for the number of times specified in the
Count field, 1: Run the command for infinite times until the
EN bit is set.

RW

3:2

Reserved, filled by 0

RO

4

ONCE
This bit shows that the error has been injected at least once
from the last time EN has been set. It will be cleared
whenever a value 1 is written to EN.

RO

7:5

Reserved, filled by 0

RO

15:8

Count
Number of times the error should be injected if the MODE is
1. When read, it shows number of times remained yet to
finish the requested count.

RW

16

HP
This bit enables K-symbol injection into Header Packet data.
0: Disabled
1: Enabled

RW

17

LC
This bit enables K-symbol injection into Link Command data.
0: Disabled
1: Enabled

RW

21:18

LOC
This 4-bit field determines the byte number of the HP or LC
on which the K-symbol should be injected. For LC, just lower
2 bits are valid (locations from 0 to 3). For HP, all bits are
meaningful (locations from 0 to 15).

RW

23:22

Reserved, filled by 0

RO

31:24

Symbol
This 8-bit field indicates the 8b encoding of the requested K-
symbol for injection.

RW