9 delay_lau, 10 insert k-sym error (lc and hp), Delay_lau – Teledyne LeCroy Voyager Exerciser Generation Script Language Manual User Manual
Page 159: Insert k-sym error (lc and hp)
![background image](/manuals/353648/159/background.png)
Teledyne LeCroy
Voyager USB 3.0 Exerciser Generation Script Language Reference Manual
150
12.1.9 DELAY_LAU
(Offset in the Register Area: 0x015C)
This command adds a specific delay to the response time of LAU.
MSB
LSB
Delay
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Count
Reserved
ONC
E
Reserved
INF
EN
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit Location
Register Description
Attributes
0
EN
0: Disable (stop error injection), 1: Enable (run error
injection)
This bit will be cleared automatically when the INF bit is not
set and the Count value is reached down to zero.
RW
1
INF
0: Run the command for the number of times specified in the
Count field, 1: Run the command for infinite times until the
EN bit is set.
RW
3:2
Reserved, filled by 0
RO
4
ONCE
This bit shows that the error has been injected at least once
from the last time EN has been set. It will be cleared
whenever a value 1 is written to EN.
RO
7:5
Reserved, filled by 0
RO
15:8
Count
Number of times the error should be injected if the MODE is
1. When read, it shows number of times remained yet to
finish the requested count.
RW
31:16
Delay
This field contains the delay time value. Granularity of the
delay time is 100ns, i.e. each unit in this field is equal to
100ns.
RW
12.1.10
Insert K-Sym Error (LC and HP)
(Offset in the Register Area: 0x0160)
This command inserts a K-sym in LC data and HP data.
MSB
LSB
Symbol
Reserved
LOC
LC
HP
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Count
Reserved
ONC
E
Reserved
INF
EN
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit Location
Register Description
Attributes
0
EN
0: Disable (stop error injection), 1: Enable (run error
injection)
RW