47
12. Precautions for Use
Shape of Y-terminal
Spacer for user part installation
M4, depth 5
30 N or less
2 N
m or less
External force applied to the spacers must not
exceed 30 N in the axial direction or 2 N
m in the
rotating direction (for each spacer).
7
12.5 User Wiring and Piping
The robot comes with standard cables and tubes that the user can use in a desired wiring/piping configuration.
User connector specifications
Rated voltage
30 V
Permissible current
1.1 A
Conductor size and number of wires
AWG 26 (0.15 mm
2
),
15 wires
Other
Twisted-pair cable
(1 to 24), shielded
Piping specifications
Normal service pressure
0.8 MPa
Dimensions (outer diameter x inner
diameter) and number of tubes
4 mm x 2.5 mm,
3 pieces
Working medium
Air
ALM (indicator) specifications
Rated voltage
24 VDC
Rated current
12 mA
Illumination color
Red LED
Quick joint
4, red
ALM (indicator)
Quick joint
4, black
Spacer for user part installation
Quick joint
4, white
BK SW
Brake-release switch
User connector
M cable
(outside
robot)
U cable
(outside robot)
PG cable
(outside robot)
BK power cable (outside robot)
Panel Rear
Panel
Air
(