14. Linear Scale Cleaning Procedure


[Required Items for Cleaning]
 Allen wrenches (4 mm, 3 mm and 2.5 mm across flats)

 Tweezers

 Dry cloth

 Industrial alcohol
 Marker pen

[Procedure]

Warning:
 This actuator uses high-performance rare-earth permanent magnets. Accordingly, anyone

who is using a pacemaker or other medical device should not perform this work.

 Do not bring a watch, mobile phone or any other electronic device susceptible to the

magnetic field closer to the actuator.

 Wear gloves and exercise caution not to cut your hand by the stainless sheet during the

procedure.

 Pay due attention not to let the permanent magnets attract iron powder or other magnetic

objects during the procedure.


Caution:

The bolts you have removed will be required when reassembling the linear scale. Keep
them in a secure place by making sure you know which bolt came from where.



(1) Remove the stainless sheet.

[1] Use an Allen wrench of 3 mm across flats to remove the bolts securing the slider cover, and take

out the slider cover.

















Slider cover