beautypg.com

Foreword, Safety precautions, 1 basic handling – IAI America LSA-W21SS User Manual

Page 15: 2 maintenance and inspection, 3 permanent magnets, Basic handling, Maintenance and inspection, Permanent magnets

background image

1


1. Foreword


Thank you for purchasing an IAI product.
This operating manual describes the correct handling, structure, maintenance and other aspects of your
actuator.
Before using your actuator, be sure to read this operating manual and handle the actuator correctly. Keep
this manual with you so that you can reference applicable information whenever necessary.

For more complete information on operating the actuator

, also peruse the operating manual for your

controller.

2. Safety Precautions

2.1 Basic

Handling


 You must assume that any handling or operation not specifically explained in this operating manual or

the

controller operating manual cannot be performed, and do not perform any such handling or

operation.

 Always

use

IAI’s genuine parts for wiring between the actuator and controller.

 Entering the operation range of the machine while the machine is operating or receiving power may

create a dangerous situation and must be avoided at all cost.

2.2 Maintenance and Inspection


Be

sure to turn off the controller power before performing maintenance or inspection.

Exercise

due caution so that other operator will not turn on the power inadvertently while inspection is

still in progress.

Put

up a plate or other sign that clearly states “WORK IN PROGRESS,” etc., in a conspicuous location.

 If two or more operators work together to perform maintenance or inspection, the operators should

mutually watch out for each other’s safety. Particularly when turning on/off the power or moving the
axis, always call out before each action to ensure safety.

2.3 Permanent

Magnets


This actuator uses high-performance rare-earth permanent magnets.
Accordingly, the actuator may cause malfunction in medical devices such as pacemakers.
Those who are wearing a pacemaker or any other medical device must not come within 30 cm of the
actuator.

(Note)
 The information provided in this manual is subject to change without notice for the purpose of

modification

and

improvement.

 This manual has been written with due attention to precision and completeness, but there may still be

inaccuracies and omissions. Should you find any error, or if you have any feedback, please contact
IAI’s Engineering Service Section or Sales Engineering Section.

This manual is related to the following products: