3 tightening screws, 4 installing a connector box using t-slots, Tightening screws – IAI America LSA-W21SS User Manual
Page 25: Installing a connector box using t-slots
![background image](/manuals/350270/25/background.png)
11
7.3 Tightening
Screws
Use hexagonal socket head bolts (male screws) for installing the base.
Use of high-tensile bolts of ISO strength category 10.9 or above is recommended.
Provide the following effective engagement length for the bolt and male screw.
When the male screw is made of steel
Same as the nominal diameter
When the male screw is made of aluminum
Twice the nominal diameter
The recommended tightening torques are as follows.
Tightening torque
Screw nominal
diameter
Steel bolt bearing surface
Aluminum bolt bearing surface
M8
31.3 N
m (3.19 kgfm) 14
N
m (1.43 kgfm)
7.4 Installing a Connector Box Using T-slots
T-slots (M4) are provided on the side faces of the actuator for installation of a connector box or other
external equipment.
If you are using a wiring kit, install a connector box using these T-slots.
T-slots can also be used for other purposes, such as installing sensors or securing cables.
The T-slot dimensions are specified below.
Use of square nuts is recommended in T-slots, but hex nuts can also be used.
When installing an object using T-slots, select bolts of an appropriate length so that the end of the bolt
will not contact the bottom of the T-slot.