8. Wiring of the Cables
Unless otherwise specified, the actuator of single-axis configuration is shipped with a 3 or 5-meter single-
axis cable preassembled with the actuator. Plug the connector at the end of the cable into the controller
directly.
The single-axis cable has excellent flexibility, but it is not a robot cable. Therefore, avoid storing this
cable in a movable wiring duct having a small bending radius.
In applications where the single-axis cable cannot be affixed, prevent the cable from deflecting except by
the dead weight, or use a self-standing cable hose or wire the cable with a large bending radius to
reduce the load received by the cable.
Do not cut any of the cables to reduce its length or reconnect the cut cable with other cable to extend the
wiring length or for any other purpose.
Do not pull the cables or bend them excessively.
If you wish to change the cable, please consult IAI.
Controller connection diagram
This is a connection example with the XSEL controller. This actuator can also be connected to the
SSEL or SCON controller.
PC software
XSEL controller
Host system (PLC)
Control power
supply, drive
power supply
Encod
er cabl
e
Motor cable
Teaching
pendant
Linear actuator