Notes on use of cable bearers

z Do not let the cable get tangled or kinked in a cable bearer or flexible tube. When bundling the cable,

keep a certain degree of flexibility (so that the cable will not become too taut when bent).

z Do not cause the cables to occupy more than

60% of the space in the cable bearer.

z Do not lay signal lines together with circuit lines

that create a strong electric field.

z The supplied cable is not a robot

cable. Accordingly, never store the
supplied cable in a cable bearer.

z Use a cable bearer with its bending

radius r set to 50 mm or greater.

z If a relay cable is to

be used, always
use a robot cable.

Bending radius r

Cable

Cable bearer

Power line

Signal lines
(flat cable)

Duct