6. Installation Environment, Storage Environment

6. Installation Environment, Storage Environment

6.1 Installation

Environment

Install the actuator in an environment meeting the conditions listed below.

x not be exposed to direct sunlight.
x be free from irradiating heat coming from a heat treatment furnace or other equipment that generates a

large amount of heat.

x have ambient temperature of 0 to 40qC.
x have humidity of 85% or below (non-condensing).
x be free from corrosive or flammable bases.
x be free from excessive dust and suitable for normal assembly work.
x be free from oil mist or cutting oil.
x be free from impact or vibration.
x be free from strong electromagnetic field, ultraviolet light or radiation.
x Chemical resistance is not considered in the design of this product.
In general, the actuator should be used in an environment where the operators can work without wearing
any protective equipment or gear.

6.2 Storage

Environment

The storage environment should basically conform to the installation environment. If the actuator is to be
stored for an extended period of time, provide appropriate measures to prevent dew condensation.
The actuator is not packed with drying agent, unless otherwise specified by the user. If the actuator is to
be stored in an environment where dew condensation may occur, take appropriate measures to protect
the entire package, or the actuator itself (after unpacking it), from the detrimental effects of dew
condensation.
The actuator can withstand an ambient temperature of up to 60

qC for a short period. If the actuator must

be stored for over a month, keep the ambient temperature at 50

qC or below.