Maintenance inspection, 1 inspection items and schedule, 2 external visual inspection – IAI America RCP2-BA7U User Manual
Page 40: 3 cleaning

4. Maintenance Inspection
34
4. Maintenance Inspection
4.1 Inspection Items and Schedule
Follow the maintenance inspection schedule below.
It is assumed that the equipment is operating 8 hours per day.
If the equipment is running continuously night and day or otherwise running at a high operating rate,
inspect more often as needed.
External visual inspection Check interior
Greasing
Belt loosening
Start of work inspection
�
1 month inspection
�
6 month inspection
�
�
12 month inspection
�
�
�
�
Every 6 months
thereafter
�
Every 12 months
thereafter
�
�
�
�
* If the actuator are operated back and forth repeatedly over a distance of 30mm or less, the oil film
created by the grease may be broken. As a guide, move the actuators back and forth repeatedly for
around 5 cycles over a distance of 50mm or more after every 5,000 to 10,000 cycles. A layer of the
grease will recover.
4.2 External Visual Inspection
An external visual inspection should check the following things.
�
Main unit
Loose actuator mounting bolts, other loose items
Cables
Scratches, proper connections
Overall
Irregular noise, vibration
�
4.3 Cleaning
• Clean the exterior as needed.
• Wipe off dirt with a soft cloth.
• Do not use strong compressed air on the actuator as this may force dust into the crevices.
• Do not use petroleum-based solvent on plastic parts or painted surfaces.
• If the unit is badly soiled, apply a neutral detergent or alcohol to a soft cloth, and wipe gently.