2. Installation
25
2.3 How to Install
This chapter explains how to install the actuator on your mechanical system.
2.3.1 General Rules on Installation
Follow the information below when installing the actuator, as a rule. Do pay attention to these items
(except with custom-order models).
�
: Possible � : Not possible
Horizontal
installation
Vertical
installation
Sideway
installation
Ceiling Mount
installation
�
Ч
Ч
�
Installation Orientation
Horizontal
Vertical
Sideway
Ceiling Mount
The figures above are motor on top side.
Caution: In the Ceiling mount installation, the belt cover may bend, and it will be likely to
interfere with the work part. When the stroke is more than 500mm for BA6 or BA6U,
or the stroke more than 600mm for BA7 or BA7U, make a gap to the slider seat to
attach a work part.
Type
Stroke
Distance A
BA6, BA6U
500mm to 1000mm
5mm or more
BA7, BA7U
600mm to 1200mm
5mm or more