beautypg.com

9 end – IAI America RCA-P User Manual

Page 39

background image

8-9 End

End is executed to save each setting or registration content of the Data Input Pendant.

Before removing the Data Input Pendant from the RC controller, be sure to execute End.

Operation:

Press the BEGIN/END key for more than 2.5 seconds.

In a case that data input ends, and the Data

Input Pendant needs to be removed

In a case that you reconnect and wish to

reopen

Op. Start / End
* End DU = Efct

Op. Start / End
* Reconnection

Op. Start / End
* End DU = Non

Confirming Connection
IAI RC DU V. 1.66

Turn the RC Controller PORT Switch to OFF.

Then, remove the connector.

Select Axis
* Axis No. 00

(in a case of multiple axes connection)

Or

Mode Select

A. 00

* Edit/Teach

(in a case of single axis connection)

Caution: When multiple axes are connected with a controller link cable, after recycling

power of a controller that is not directly connected to the Data Input Pendant,

please execute a reconnect.

35