beautypg.com

Ronan X96S MOLD LEVEL GAGE User Manual

Page 54

background image

50

4 relay (2 Amp capacity) output points are provided. Form “C” outputs are brought out to the connector (three connections per
relay).

4 isolated open collector output points are provided. These outputs are capable of switching 4.5 to 30 Volts (externally supplied)
at a maximum of 50 mA.

24 volts DC is provided to be used as a wetting voltage when needed.

An isolated 15 volt DC power supply capable of providing 200 mA is also provided. The primary use of this power supply is to
power a quadrature encoder but can be used for other purposes if it is not required for this purpose.

X96-2009PL1

X96-2009PL1 is the Scintiallation Detector Interface Module. This optional

5

module provides:

• 1 isolated scintillation input (pulse counter, max signal 0-12

6

V, threshold 0.6 V)

• 1 head temperature input (1 uA per deg K)

• 1 non-isolated RTD (3-wire) input

• isolated power for the scintillation detector 24 V 40 mA supply

7

.

X96-2009PL2

X96-2009PL2 is the Scintillation Board with ch. 2 modified for 0-20 mA input instead of RTD

X96-2009PL3

X96-2009PL3 is the Scintillation Board with ch. 2 modified for 0-10Vdc input instead of RTD

X96-2029PL

X96-2029PL is the Mold Level Module (board) for scintillation detector, with two digital inputs, two analog outputs and two
digital outputs (1 relay, 1 TTL).

X96C148

X96C148 is the 85 to 230 Volt power supply module

X96C148-2

X96C148-2 is the 24 Volt DC power supply module

X96C148-4

X96C-148-4 is the 12 V DC “in”, 24 V DC “out” 50 watt power supply module

5

At least one detector interface module is required.

6

8.6 V nominal.

7

The power supply has the ability to control the power to the scintillation detector:

• when commanded by the CPU module,

• when the processor on the module detects a condition that could harm the scintillation detector,

• when the watchdog timer generates a reset.