beautypg.com

Diagnostics – Ronan X96S MOLD LEVEL GAGE User Manual

Page 28

background image

24

DIAGNOSTICS

This menu is used to provide the available variables needed to troubleshoot on one simple screen. It contains the following items:

ITEM

MEANING

Raw Counts

Non-filtered counts from the detector

Filtered Counts

X96S filtered counts from the detector

Nonlinear

Shows the current state of the mold level (No curve correction used)

Last Ref. Date

Shows the date the last low calibrate was performed

Low Cal Level

Shows the current value of the low cal level variable

High Cal Level

Shows the current value of the high cal level variable

Low Cal Cnts

Shows the raw captured counts for the low calibration

High Cal Cnts

Shows the raw captured counts for the high calibration

MLM Out 1

Shows the current output from MLM 1

MLM Out 2

Shows the current output from MLM 2

Alarms

Information available for troubleshooting the alarms