beautypg.com

Electronics – Ronan X96S MOLD LEVEL GAGE User Manual

Page 53

background image

49

Electronics

X96-2001PL

X96-2001PL is the CPU module

X96-2003-01PL

X96-2003-01PL is the Ionization Chamber Input

X96-2003-02PL

X96-2003-02PL is the PCB assembly, analog input, 0-5 volt on both channels

X96-2003-03PL

X96-2003-03PL is the PCB assembly, analog input, 0-20mA on both channels

X96-2003-04PL

X96-2003-04PL is the PCB assembly, analog input, two wire transmitter

X96-2003-05PL

X96-2003-05PL is the analog input, 0-15 volt on both channels

X96-2004PL

X96-2004PL is the 2-Channel Analog Output Module. This optional module has two isolated analog outputs each of which can be
independently configured as a:
• 4-20 mA current loop,

• a source of 0 to 10 volts, or

• a sink of 0 to 20 mA.

X96-2005PL

X96-2005PL is the HART Daughter Module. This module provides both a 4-20 mA current loop and a HART slave interface.

X96-2008PL

X96-2008PL is the Digital Input/Output Module. A total of 16 bits of digital I/O and wetting/encoder power is provided by the
module.

8 isolated digital inputs are provided. These inputs can be configured for use as:
• dry

2

or live

3

contact monitoring,

• quadrature encoder

4

, or

• pulse counter.

2

When used with dry contacts, jumpers shall be used on the connector block to provide the wetting voltage. When used in this

mode, input to input isolation is not maintained.

3

When used with live contacts, each input shall be able to accept up to 30 volts DC. Zero volts to 0.8 volts are recognized as a

logic zero and 2.5 volts to 20 volts are recognized as logic one.

4

The interface to the quadrature encoder shall consist of two inputs, 15 volts DC at 200 mA (described in a later section), and

common.