Electronics – Ronan X96S MOLD LEVEL GAGE User Manual
Page 53
49
Electronics
X96-2001PL
X96-2001PL is the CPU module
X96-2003-01PL
X96-2003-01PL is the Ionization Chamber Input
X96-2003-02PL
X96-2003-02PL is the PCB assembly, analog input, 0-5 volt on both channels
X96-2003-03PL
X96-2003-03PL is the PCB assembly, analog input, 0-20mA on both channels
X96-2003-04PL
X96-2003-04PL is the PCB assembly, analog input, two wire transmitter
X96-2003-05PL
X96-2003-05PL is the analog input, 0-15 volt on both channels
X96-2004PL
X96-2004PL is the 2-Channel Analog Output Module. This optional module has two isolated analog outputs each of which can be
independently configured as a:
• 4-20 mA current loop,
• a source of 0 to 10 volts, or
• a sink of 0 to 20 mA.
X96-2005PL
X96-2005PL is the HART Daughter Module. This module provides both a 4-20 mA current loop and a HART slave interface.
X96-2008PL
X96-2008PL is the Digital Input/Output Module. A total of 16 bits of digital I/O and wetting/encoder power is provided by the
module.
8 isolated digital inputs are provided. These inputs can be configured for use as:
• dry
2
or live
3
contact monitoring,
• quadrature encoder
4
, or
• pulse counter.
2
When used with dry contacts, jumpers shall be used on the connector block to provide the wetting voltage. When used in this
mode, input to input isolation is not maintained.
3
When used with live contacts, each input shall be able to accept up to 30 volts DC. Zero volts to 0.8 volts are recognized as a
logic zero and 2.5 volts to 20 volts are recognized as logic one.
4
The interface to the quadrature encoder shall consist of two inputs, 15 volts DC at 200 mA (described in a later section), and
common.