Mold level config menu, Head temp config menu, Alarms – Ronan X96S MOLD LEVEL GAGE User Manual
Page 19
15
ITEM
FUNCTION
Table Entry #
Shows and allows the user to select an entry in the linearization table
Entry Used
Shows if the entry is used or not
Measured
Shows and allows the user to set the measured value associated with this linearization
table entry. This is a value calculated by the X96S
Actual
Shows and allows the user to set the actual value associated with this linearization
table entry. This value is the result of actual mold level knowledge, and compares to
the Measured value above
Set Entry
This item invokes a method that sets a table entry
Remove Entry
This item invokes a method that removes a table entry
Mold Level Config Menu
The Mold Level Config menu is used to configure the parameters associated with the mold level measurement. It contains
the following items:
ITEM
FUNCTION
Units
Shows and allows the user to set the mold level units used
Low Range
Shows and allows the user to set the mold level value to be mapped to 4mA on the
current loop output, if mold level is selected to control that current loop
High Range
Shows and allows the user to set the mold level value to be mapped to 20mA on the
current loop output, if mold level is selected to control that current loop
Units is one of the following:
UNITS
MEANING
Ft
Feet
M
Meter
In
Inch
Cm
Centimeter
Mm
Millimeter
Head Temp Config Menu
The Head Temp Config menu is used to configure the parameters associated with the detector electronics temperature
measurement. This function is used primarily in high-temperature applications where the temperature exceeds the electronics
temperature specifications. It contains the following items:
ITEM
FUNCTION
Temp Units
Shows and allows the user to set the units to be used for head temperature
Low Range
Shows and allows the user to set the temperature value to be mapped to 4mA on the
current loop output, if head temperature is selected to control that current loop
High Range
Shows and allows the user to set the temperature value to be mapped to20mA on the
current loop output, if head temperature is selected to control that current loop
Alarms
The
Alarms
menu is used to configure the parameters associated with the analog alarms. This applies to alarms 1-7 as well as
Start-Cast and 4-20mA alarm.
ITEM
FUNCTION
Source
Shows and allows the user to set the source of the alarm
Alarm Type
Shows and allows the user to set the alarm type
Valid Scans
Shows and allows the user to set the number of consecutive scans before signaling the
alarm to trip