Detector Removal/
Replacement
ELONGATED DETECTOR NOTES:
To avoid damage in shipment or installation, the
elongated detector is packaged separate from the
housing. Avoid subjecting detectors to mechanical
shock. Avoid supporting detector by its chain handle,
or other lifting devices, for prolonged periods of time.
When the detector is properly seated on the bottom of
the housing, the hold-down clamp “tab” will engage
and the extension rod screw can be adjusted to tighten
the detector assembly into housing.
DETECTOR HOUSING/
BRACKET ASSEMBLY NOTES:
Many detectors are shipped inside the housing/bracket
assembly. Bolts at the top and bottom of the C-Clamp
are used to adjust the assembly around a pipe.
1) Check NOTES below for illustrations
and cautions that apply to your specific
equipment.
2) Unscrew cap on detector housing.
3) Unscrew connector on top of detector.
4) Remove detector from housing.
5) Carefully install replacement detector in
housing.
6) Screw connector back onto detector.
7) Immediately replace detector-housing
Detector Housing
Cap
Detector Housing
Cable Connector
Detector