Configuration menu, Status display menu – Ronan X96S MOLD LEVEL GAGE User Manual
Page 16
12
Status Display Menu
The Status Display menu is used to configure the device status display. It contains the following items
ITEM
FUNCTION
Analog Bar
Shows the current state of the analog bar display (enabled or disabled) and allows the
user change the state
Line 1:
Shows the data to be displayed on line 1 of the status display and allows the user to
change the selection
Line 2:
Shows the data to be displayed on line 2 of the status display and allows the user to
change the selection
Line 3:
Shows the data to be displayed on line 3 of the status display and allows the user to
change the selection
Line 4:
Shows the data to be displayed on line 4 of the status display and allows the user to
change the selection
Line 5:
Shows the data to be displayed on line 5 of the status display and allows the user to
change the selection
Line 6:
Shows the data to be displayed on line 6 of the status display and allows the user to
change the selection
Line 7:
Shows the data to be displayed on line 7 of the status display and allows the user to
change the selection
Line 8:
Shows the data to be displayed on line 8 of the status display and allows the user to
change the selection
Each line may select one of the following:
SELECTION
MEANING
Level
Level [Std. Update]
Nonlinear
Nonlinear level [no curve correction]
MLM Level 1
Level [Fast Updates]
MLM Level 2
Level [Fast Updates]
Head Temp
Head temperature [if available]
4-20 mA
4-20 mA output level
Raw Counts
Raw counts (from scintillation detector) or raw analog measurement (from ionization
detector (non-filtered)
Filtered Counts
Filtered counts (from scintillation detector) or (from ionization detector)
Date & Time
Current date and time
MLM Out 1
Output from MLM 1
MLM Out 2
Output from MLM 2
MLM Filter 1 Monitor
Shows the current state of the filtering mechanism for MLM 1
MLM Filter 2 Monitor
Shows the current state of the filtering mechanism for MLM 2
Diagnostic
Selecting this choice takes the user to the Diagnostic Menu
Not Assigned
Blank line
Configuration Menu
The Configuration menu is used to access area configuration menus. It contains the following items:
ITEM
FUNCTION
Operation
Selecting this choice takes the user to the Operation menu
Level Config
Selecting this choice takes the user to the Level Config menu
Head Temp Config
Selecting this choice takes the user to the Head Temp Config menu
Alarms
Selecting this choice takes the user to the Alarm menu
Hardware
Selecting this choice takes the user to the Hardware menu
HART
Selecting this choice takes the user to the HART menu
System
Selecting this choice takes the user to the System menu