Operation - delivery setup – Liquid Controls LCR 600 Setup & Op User Manual
Page 49
![background image](/manuals/336508/49/background.png)
49
delIvery Setup 1
product & Calibration details
(fE)
u - l
C1 PT1 GAS 91
Gasoline
The calibration number, calibration code, calibration name
and calibration type of the active calibration
Calibration Code:
(fE)
u - l
The code assigned to the active calibration. Often, this code
corresponds with an office code.
Calibration Name:
(fE)
u - l
The text designation of the active calibration.
Preset Type:
(LB)
u
Provides four options for handling preset deliveries.
Clear
resets the preset values to 0 after the current delivery is ended.
Retain
maintains the preset values to be used again on the next delivery.
Multiple
allows more than one preset to be run before a delivery ticket is printed. Delivery ticket printed with PRINT command.
Inventory
maintains the remaining preset amount between deliveries. Typically used to indicate the remaining volume in the vehicle tank.
Net Preset:
(fE)
u - l - p
Preset value according to net volume.
Gross Preset:
(fE)
u - l - p
Preset value according to gross volume.
Price/Unit:
(fE)
u - l - p
The active price per unit of measure.
Tax/Unit:
(fE)
u - l
The active tax per unit of measure.
Percent Tax:
(fE)
u - l
The percentage of the total price added to the total price as a tax.
Total Price:
Display Only
The total price of the active delivery.
No-Flow Timer:
(fE)
u - l
The amount of time until the LCR 600 ends a delivery and prints a ticket after it senses that no product is flowing
through the meter. The time can be set from 0 to 3600 seconds. If the time is set as 0, the feature is deactivated and
the message “Multiple Deliveries at One Site” will be printed on the delivery ticket. If the value is greater than 180, the
message “Multiple Deliveries at One Site” will be printed on the delivery ticket. The No-Flow Timer protects product
from being delivered to unauthorized locations sometimes referred to as “riding the ticket”. Increasing the value allow
fuelers to deliver fuel to more than one tank (or fueling point) at a single site and print one ticket that includes every
tank at that site. The No-Flow Timer is not active in the calibration mode.
Net Quantity:
Display Only
The net quantity of the active delivery.
Gross Quantity:
Display Only
The gross quantity of the active delivery.