delIvery Setup 1

product & Calibration details

(fE)

u - l

C1 PT1 GAS 91

Gasoline

The calibration number, calibration code, calibration name
and calibration type of the active calibration

Calibration Code:

(fE)

u - l

The code assigned to the active calibration. Often, this code

corresponds with an office code.

Calibration Name:

(fE)

u - l

The text designation of the active calibration.

Preset Type:

(LB)

u

Provides four options for handling preset deliveries.

Clear

resets the preset values to 0 after the current delivery is ended.

Retain

maintains the preset values to be used again on the next delivery.

Multiple

allows more than one preset to be run before a delivery ticket is printed. Delivery ticket printed with PRINT command.

Inventory

maintains the remaining preset amount between deliveries. Typically used to indicate the remaining volume in the vehicle tank.

Net Preset:

(fE)

u - l - p

Preset value according to net volume.

Gross Preset:

(fE)

u - l - p

Preset value according to gross volume.

Price/Unit:

(fE)

u - l - p

The active price per unit of measure.

Tax/Unit:

(fE)

u - l

The active tax per unit of measure.

Percent Tax:

(fE)

u - l

The percentage of the total price added to the total price as a tax.

Total Price:

Display Only

The total price of the active delivery.

No-Flow Timer:

(fE)

u - l

The amount of time until the LCR 600 ends a delivery and prints a ticket after it senses that no product is flowing

through the meter. The time can be set from 0 to 3600 seconds. If the time is set as 0, the feature is deactivated and
the message “Multiple Deliveries at One Site” will be printed on the delivery ticket. If the value is greater than 180, the

message “Multiple Deliveries at One Site” will be printed on the delivery ticket. The No-Flow Timer protects product

from being delivered to unauthorized locations sometimes referred to as “riding the ticket”. Increasing the value allow
fuelers to deliver fuel to more than one tank (or fueling point) at a single site and print one ticket that includes every

tank at that site. The No-Flow Timer is not active in the calibration mode.

Net Quantity:

Display Only

The net quantity of the active delivery.

Gross Quantity:

Display Only

The gross quantity of the active delivery.

operatIon - delIvery Setup

l - locked
u - unlocked
c - Weights & measures calibration
p - Stop/pause
f - factory

Security clearance

fE - field Edit Box
LB - List Box

field type