Clear-Com BS850 (Last time buy) User Manual
Page 48
45
System (Voltages and Temperature) Status
Base station power supply voltages are shown. The 12V box shows the actual input voltage supplied
to the base station. Each of the other voltages should be within +10% of the marked value. The T
°C
box shows base station internal temperature in degrees Celsius.
Beltpac Status
Beltpac status shows Beltpac Name, assigned Base, current Beltpac Talk status, Beltpac Battery
level, Beltpac Tx Power level and Beltpac transmit signal level.
The BASE box shows which base in a master/slave configuration is actually receiving that
particular Beltpac.
The Talk box shows if Beltpac user is pressing Talk button.
The Batt box shows battery status of the selected Beltpac (OK, Low or Dead).
The Tx Pwr box shows the current transmitter power level of the selected Beltpac.
The Signal box indicates how well the Beltpac is receiving transmission (Low, OK or High)
from the base station.
Beltpac transmit can be aborted by clicking on the corresponding row of the Beltpac status table and
pressing on Stop Tx button. This will stop a latched-on Beltpac from transmitting.
When a Beltpac’s status is shown as unknown, that indicates the Beltpac is either turned off or in PTS
mode, and not currently transmitting. Status will always be displayed for all Beltpacs that are on and
in PTT or PTE modes. Status for Beltpacs in PTS mode is only shown while those Beltpacs are in
Talk operation.