System Status:

The Status screen shows the operational status of the entire PRO850 system. Status information is
available on this screen for the base station and all of the Beltpacs. In a master/slave configuration,
only the status for the selected base is displayed. Other base(s) can be selected from the list in the
upper left. The status for all Beltpacs is displayed no matter which base is selected.

NOTE: You can only access this display while connected to a Base station, and online.

NOTE: To move this screen relative to the other windows on the desktop, press the
“Freeze Screen” button. This will pause communication from the base station until the
button is unlatched.

Receiver Status
Receiver status shows current Rx Signal and Rx Tuning levels for all BS850 receivers.
There are separate signal-strength and tuning meters for each receiver module in the base. Signal-
strength meters fill in from left to right with increasing signal strength.
When a signal is being received, the tuning indicator should be near the zero at the center of the
scale. The absolute position is not critical. When no signal is being received, the tuning indicator
may be offset to the left or right. If a tuning indicator is far to one side, it indicates the presence of a
strong signal on an adjacent frequency. In that case, it is advisable to change to a different frequency
to avoid interference or range problems.

Transmitter Status
Transmitter status shows current Power mode, Power Level and Frequency settings for both BS850
transmitters.