19
Technicaldata
fluid pressure
• 8026
• 8036
• 8076 with a fitting S070 of DN15
• 8076 with a fitting S070 of DN25
• 8076 with a fitting S070 of DN40 or DN50
• 8076 with a fitting S070 of DN80
• 8076 with a fitting S070 of DN100
Also refer to the requirements of the Pressure Directive: see
chap. 6.2.2
• PN10; Also factor in the fluid temperature/pressure
dependency for the 8026 inserted into an S020 fitting (see
Figure 5)
• PN16; Also factor in the fluid temperature/pressure
dependency for the 8036 (SE36 mounted on an S030 fitting):
see Figure 6
• max. 55 bar
• max. 55 bar (or the rules governing the flanges)
• max. 18 bar
• max. 12 bar
• max. 10 bar
type of fluid
• 8026 and 8036
• 8076
• Neutral or slightly aggressive fluids
• Viscous fluids, free of solid particles
fluid viscosity
• 8026 and 8036
• 8076
• 300 cSt max.
• Refer to the operating manual for fitting S070
solid particle rate in the fluid
• 8026 and 8036
• 8076
• ≤ 1%
• 0 %
flow rate measurement
• Measurement range
• Linearity
• Repeatability
• Measurement error with standard K factor
• measurement error with a Teach-in
procedure
• 0,3 to 10 m/s
• ±0,5%
2)
of the full scale
• ±0,4%
2)
of the measured value
• ±2,5%
2)
of the measured value
• ±1%
2)
of the measured value (at the teach-in point)
1)
and PVDF paddle wheel
2)
Determined in the following reference conditions: fluid = water, water and ambiant temperatures = 20 °C, upstream and
downstream distances respected, appropriate pipe dimensions.
6.3.3.
electrical data
Power supply
• version with 2 or 3 outputs (2 wires)
• version with 4 outputs (3 wires)
• 14-36 V DC, filtered and regulated
• 12-36 V DC, filtered and regulated
English