Technicaldata
6.
TechnicAl DATA
6.1.
conditions of use
Ambient temperature
-10 to +60 °C
Air humidity
< 85%, non condensated
Protection rating
IP67 and IP65 with connectors plugged in and tightened and electronic
module cover fully screwed down
6.2.
conformity to standards and directives
6.2.1.
conformities common to the 8026 and the se36
• EMC: EN 61000-6-2, EN 61000-6-3
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
For UL devices (
) in the United States of America and Canada:
• UL 61010-1
• CAN/CSA-C22.2 n° 61010-1
6.2.2.
conformity to the pressure directive of flowmeters 8026
and fittings s030 and s070
The devices 8026 and the fittings S030 and S070 comply with article 3§3 of the pressure directive.
Acc. to the 97/23/CE pressure directive, the product can only be used in the following cases (depending on max.
pressure, pipe diameter and fluid):
type of fluid
conditions
Fluid group 1, par. 1.3.a
• Flowmeter 8026 and fitting S030: DN ≤ 25 only
• Fitting S070: Forbidden
Fluid group 2 par. 1.3.a
DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
Fluid group 1 par. 1.3.b
• Flowmeter 8026: DN ≤ 25 or DN > 25 and PNxDN ≤ 2000
• Fittings S030 and S070: PNxDN ≤ 2000
Fluid group 2 par. 1.3.b
• Flowmeter 8026: DN ≤ 400
• Fittings S030 and S070: DN ≤ 200
English
Type 8026- 8036- 8076