Datamax-O'Neil Performance series User Guide User Manual
Page 110
![background image](/manuals/327576/110/background.png)
4 | Menu System
Performance Series User’s Guide
132
The Sensor Readings function allows the user to view the values of various printer
sensors. The Sensor Readings menu has four (4) tabs that can be navigated by
selecting the next and previous buttons in the taskbar.
b. General
Select General to enable or disable the appropriate settings:
•
Page Format Shading - Used for diagnosing label format issues, enabling this
options puts a shade over white areas of the image on a label.
Test Options
The Test Options function of the Diagnostics menu allows the user to test the options
currently installed on the printer. Select Test Options and navigate through the tabbed
interface to select the option to be tested. The tabs are navigated using the next and
previous arrows in the taskbar.
Table 22: Test Options
Once the selections have been made, select the Start button to begin the test.
Test GPIO
The Test GPIO function allows the user to test a connected applicator.
Table 23: Test GPIO
Test Options
Values
Ranges
Default
Cycle Cutter
1 to 999
1
Test Present Sensor
N/A
Test Rewinder
N/A
Test Ribbon Assembly
•
Select Spindle
Front
Rear
N/A
Selections
Values
Ranges
Default
Enable Wrap Around
Enabled
Disabled
Disabled
Pulse Width
1 to 2000
1000
I/O Configuration
Sig 1/2
Input
Output
Input
Sig 3/4
Input
Output
Input