beautypg.com

Analog Way Smart Quad User Manual

Page 64

background image

If you need to use your own Software Control program from a

PC or automation, the device allows communication through an

ASCII code protocol. All commands can be found on our website:

www.analogway.com

All Analog Way products equipped with an RS232 input are

compatible with Crestron, AMX, Medialon, and most major control

systems. TCP/IP control ports are also available on most Analog

Way products, as standard or as options.

To control an

SQD200

product with an External Remote Controller

(PC Software Control - Touch Pad Controller…) follow the indications

below:

1. First establish a connection between the Remote Control Software
and the

SQD200

. Select the RS232/LAN option from the “Control”

menu, and the equivalent in your RCS.
If using RS232 no further setup is required.

2. If using a LAN setup select the TCP / UDP option from the “LAN

setup” menu.

3. Configure the LAN address in your RCS eg 192.168.000.001.

4. Configure the TCP option from the “LAN setup” menu.

In example on the Remote Software in the “Control” - “RS232/LAN

Setup” - “LAN/Setup” menu.

5. Setup the LAN parameters in UDP mode in the “Console” - “LAN

Setup” menu.

Example:

Device address 192.168.0.2

Gateway

192.168.0.1

Device port

10500

Netmask

255.255.255.000

If using a UDP LAN connection you must set up the Remote address

and Remote Port as well.

Once the connection has been setup, you can use your RCS to
control your

SQD200

.

7-1. EXTERNAL PROGRAMMING

62

EXTERNAL PROGRAMMING