B&K Precision 4045B - Manual User Manual
Page 84

84
SWRAte
SWSTArt
SWSTOp
MODE CONT/ TRIG / GATE / BRST
TRIG INT / EXT
TRAte
BURSt
FREQuency
The frequency command controls the frequency of
the output waveform.
Arguments
Type: Numeric.
Units: MHz, KHz, Hz (default)
Range: For SIN and SQU – 0.1 Hz to Max.
frequency (see specifications),
For TRI – 0.1 Hz to 1 MHz,
For ARB - Dependent on the Point Rate and
Wavelength.
Fmax = 1/(20nS * Wavelength)
Fmin = 1/(50S * Wavelength)
Rounding: The value is rounded to 5 digits or 100 mHz.
(DDS) or 4 digits (ARB)
Command Type: Setting or Query
Setting
Syntax: FREQuency
FREQuency
Examples: FREQ 5KHZ
See also other documents in the category B&K Precision Generators:
- 4040B - Datasheet (3 pages)
- 4040A - Datasheet (1 page)
- 4030 - Datasheet (1 page)
- 4012A - Datasheet (1 page)
- 4013B - Datasheet (2 pages)
- 4005DDS - Datasheet (1 page)
- 4011A - Datasheet (1 page)
- 3003 - Datasheet (1 page)
- 4003A - Datasheet (1 page)
- 2005B - Datasheet (1 page)
- 4001A - Manual (19 pages)
- 4010A - Manual (39 pages)
- 4005DDS - Manual (21 pages)
- 4011A - Manual (39 pages)
- 4007B - Manual (20 pages)
- 4030 - Manual (21 pages)
- 4017A - Manual (21 pages)
- 4014B - Manual (84 pages)
- 4052-4055 - Manual (78 pages)
- 4052-4055 - Datasheet (5 pages)
- 4052-4055 - Programming Manual (33 pages)
- 4040A - Manual (25 pages)
- 4045B - Datasheet (3 pages)
- 4084-4087 - Manual (60 pages)
- 4084-4087 - Datasheet (2 pages)
- 4075 - Manual (103 pages)
- 4075 - Datasheet (4 pages)
- 4084AWG - Datasheet (2 pages)
- 4076 - Manual (106 pages)
- 4076 - Datasheet (4 pages)
- 4033 - Manual (72 pages)
- 4033 - Datasheet (3 pages)
- 262 - Datasheet (1 page)
- 1275 - Datasheet (1 page)
- 1211E - Datasheet (1 page)
- 1280B - Manual (8 pages)
- 1280B - Datasheet (1 page)
- 1249B - Manual (41 pages)
- 1253 - Datasheet (1 page)
- 1253 - Manual (37 pages)