Digital i/q 1 to 4 (r&s, Cmw-b520f option), Digital i/q interface – Atec Rohde-Schwarz-CMW500 User Manual

Page 67: Aux interface, Included extras

background image

Version 11.00, May 2013

Rohde & Schwarz R&S

®

CMW500 Wideband Radio Communication Tester 67

Digital I/Q 1 to 4 (R&S

®

CMW-B510F option) and

digital I/Q 5 to 8 (R&S

®

CMW-B520F option)

52

The R&S

®

CMW-B510F option makes the first digital I/Q interface and AUX interface and the R&S

®

CMW-B520F option makes the

second digital I/Q interface and AUX interface available on the rear of the instrument.

Digital I/Q interface

The digital I/Q interface can be used for connecting the R&S

®

CMW to the digital I/Q interface of other Rohde & Schwarz instruments

(e.g. R&S

®

AMU200A, R&S

®

EX-IQ-Box).

DIG I/Q IN 1/3/5/7

input

26-pin MDR connector

Level

LVDS

Clock rate in

100 MHz

Clock rate out

100 MHz

DIG I/Q OUT 2/4/6/8

output

26-pin MDR connector

Level

LVDS

Clock rate

100 MHz

Control signals

general-purpose control, for future use

6 signals

100 MHz

I/Q data

Resolution

for clock rate up to 100 MHz

18 bit for I and 18 bit for Q

I/Q sample rate

Source

internal, digital input, digital output,

Range

1.92 Msample/s to 100 Msample/s

Predefined values

53

standard-independent

100

Msample/s

WCDMA, LTE

1.92 Msample/s, 3.84 Msample/s,
7.68 Msample/s, 9.6 Msample/s,
15.36 Msample/s, 19.2 Msample/s,
30.72 Msample/s

I/Q enable/request rate

Digital input

transfer mode 1 (enable mode)

75 MHz, 100 MHz

transfer mode 2 (request mode)

0 Hz to 100 MHz

Digital output

transfer mode 1 (enable mode)

100 MHz

transfer mode 2 (request mode)

0 Hz to 100 MHz

AUX interface

The AUX interface can be used for connecting the R&S

®

CMW to other instruments, e.g. to trigger, clock and enable signals.

AUX A/B/C/D

bidirectional, half-duplex BNC

connectors

Level

3.3 V TTL

Clock rate

0 Hz to 100 MHz

Included extras

Digital I/Q cable (two sets)

same cable as included in R&S

®

SMU-Z6

26-pin MDR connector

52

R&S

®

CMW500 and R&S

®

CMW270 only.

53

Further values in the range from 400 sample/s to 100 Msample/s can be provided on request.