beautypg.com

Possible configurations with four rf paths – Atec Rohde-Schwarz-CMW500 User Manual

Page 15

background image

Version 11.00, May 2013

Rohde & Schwarz R&S

®

CMW500 Wideband Radio Communication Tester 15

Possible configurations with four RF paths

7

Necessary hardware (H570, H571B, H590D):
Selections: R&S

®

CMW-S590D RF frontend (ADV.) and R&S

®

CMW-S570 RF TRX.

Options: R&S

®

CMW-B590D RF frontend (ADV.) and:

- one R&S

®

CMW-B570 RF TRX and two R&S

®

CMW-B571B RF TX

- or three R&S

®

CMW-B570 RF TRX.

Configuration with two H570 (RF TRX), two H571B (RF TX) and two H590D (RF frontend (ADV.))

The R&S

®

CMW-B570 option, two R&S

®

CMW-B571 options and R&S

®

CMW-B590D option make the four RF paths (RF path 1 RX and

TX, RF path 2 RX and TX, RF path 3 TX only, RF path 4 TX only) available on the front of the instrument at connectors RF1 COM,
RF2 COM, RF1 OUT and RF3 COM, RF4 COM, RF3 OUT.

RF path 1, 2, 3 and 4 routed to separate connectors

RF generator 1 and RF generator 3

switchable to RF1 COM, RF2 COM,
RF1 OUT

see general technical specifications

RF generator 2 and RF generator 4

switchable to RF3 COM, RF4 COM,
RF3 OUT

see general technical specifications

RF analyzer 1

switchable to RF1 COM, RF2 COM

see general technical specifications

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value

RF analyzer 2

switchable to RF3 COM, RF4 COM

see general technical specifications

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value


RF path 1, RF path 3 routed to common connector and RF path 2, RF path 4 routed to common connector

RF generator 1 and RF generator 3

switchable to RF1 COM, RF2 COM,
RF1 OUT

see general technical specifications

Output level range

peak envelope power (PEP)

the specified value is valid for the total
power of the two RF generators, see
general technical specifications

Output level uncertainty

for each carrier

see general technical specifications,
+ 0.2 dB

Signal-to-noise ratio

for the carrier with the highest output level
(at least 3 dB higher than the other carrier)

see general technical specifications

RF generator 2 and RF generator 4

switchable to RF3 COM, RF4 COM,
RF3 OUT

see general technical specifications

Output level range

peak envelope power (PEP)

the specified value is valid for the total
power of the two RF generators, see
general technical specifications

Output level uncertainty

for each carrier

see general technical specifications,
+ 0.2 dB

Signal-to-noise ratio

for the carrier with the highest output level
(at least 3 dB higher than the other carrier)

see general technical specifications

RF analyzer 1

switchable to RF1 COM, RF2 COM

see general technical specifications

Level uncertainty

70 MHz to 3300 MHz

see general technical specifications,
+ 0.2 dB

3300 MHz to 6000 MHz

see general technical specifications,
+ 0.3 dB

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value

7

R&S

®

CMW500 only.