Cdma2000, 1xev-do signaling (prerequisite: r&s, Cmw-ks880, r&s – Atec Rohde-Schwarz-CMW500 User Manual
Page 65: Cmw-b200a, r&s, Cmw-b230a options), Code domain, Spectrum measurements, Power meter
Version 11.00, May 2013
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 65
Code domain
Filter
1.23 MHz, RRC, α = 0.22, CDMA filter
Level range
–28 dBm to +42 dBm
50
Measured parameters
numeric values of current, average,
max. and min. values
code domain power (CDP),
code domain error (CDE)
graphical
code domain power versus code,
code domain error versus code
Code domain power versus code
Uncertainty
< 0.4 dB
Measurement length
half-slot
1024 chip (833.33 µs)
Code domain error versus code
Measurement uncertainty
< 0.4 dB
Measurement length
half-slot
1024 chip (833.33 µs)
Spectrum measurements
Adjacent channel power
RMS detector, at the selected frequency
offsets
Filter
30 kHz Gaussian
Frequency offset interval
up to 10 adjacent channels on each side
–4 MHz to +4 MHz to each carrier
Dynamic range
> 70 dB
Expected nominal power setting for full
dynamic range
RF1 COM, RF2 COM
+1 dBm to +42 dBm
50
Uncertainty
for –43 dBc adjacent channel level
< 0.5 dB
Measurement length
half-slot
1024 chip (833.33 µs)
Power meter
MS power
Filter narrowband
bandpass,
1.25
MHz
Filter
wideband
bandpass, 8 MHz for single carrier or
16 MHz for multicarrier
Level range
–55 dBm to +42 dBm
50
Level uncertainty
see general technical specifications
Measurement length
half-slot
1024 chip (833.33 µs)
CDMA2000
®
1xEV-DO signaling (prerequisite: R&S
®
CMW-KS880,
R&S
®
CMW-B200A, R&S
®
CMW-B230A options)
Frequency range
Band class 0 to band class 19
DL
see CDMA2000
®
1xEV-DO RF generator
specifications
UL see
CDMA2000
®
1xEV-DO RF analyzer
specifications
Output level range
depending on PAR
see general technical specifications
Output level uncertainty
see general technical specifications
Output level resolution
see general technical specifications
Modulation
Dual BPSK
1.2288 Mcps
Waveform quality (rho)
> 0.99
Supported applications
Test applications
FTAP/RTAP, FETAP/RETAP
50