beautypg.com

Cdma2000, 1xev-do signaling (prerequisite: r&s, Cmw-ks880, r&s – Atec Rohde-Schwarz-CMW500 User Manual

Page 65: Cmw-b200a, r&s, Cmw-b230a options), Code domain, Spectrum measurements, Power meter

background image

Version 11.00, May 2013

Rohde & Schwarz R&S

®

CMW500 Wideband Radio Communication Tester 65

Code domain

Filter

1.23 MHz, RRC, α = 0.22, CDMA filter

Level range

–28 dBm to +42 dBm

50

Measured parameters

numeric values of current, average,
max. and min. values

code domain power (CDP),
code domain error (CDE)

graphical

code domain power versus code,
code domain error versus code

Code domain power versus code

Uncertainty

< 0.4 dB

Measurement length

half-slot

1024 chip (833.33 µs)

Code domain error versus code

Measurement uncertainty

< 0.4 dB

Measurement length

half-slot

1024 chip (833.33 µs)

Spectrum measurements

Adjacent channel power

RMS detector, at the selected frequency
offsets

Filter

30 kHz Gaussian

Frequency offset interval

up to 10 adjacent channels on each side

–4 MHz to +4 MHz to each carrier

Dynamic range

> 70 dB

Expected nominal power setting for full
dynamic range

RF1 COM, RF2 COM

+1 dBm to +42 dBm

50

Uncertainty

for –43 dBc adjacent channel level

< 0.5 dB

Measurement length

half-slot

1024 chip (833.33 µs)

Power meter

MS power

Filter narrowband

bandpass,

1.25

MHz

Filter

wideband

bandpass, 8 MHz for single carrier or
16 MHz for multicarrier

Level range

–55 dBm to +42 dBm

50

Level uncertainty

see general technical specifications

Measurement length

half-slot

1024 chip (833.33 µs)

CDMA2000

®

1xEV-DO signaling (prerequisite: R&S

®

CMW-KS880,

R&S

®

CMW-B200A, R&S

®

CMW-B230A options)

Frequency range

Band class 0 to band class 19

DL

see CDMA2000

®

1xEV-DO RF generator

specifications

UL see

CDMA2000

®

1xEV-DO RF analyzer

specifications

Output level range

depending on PAR

see general technical specifications

Output level uncertainty

see general technical specifications

Output level resolution

see general technical specifications

Modulation

Dual BPSK

1.2288 Mcps

Waveform quality (rho)

> 0.99

Supported applications

Test applications

FTAP/RTAP, FETAP/RETAP

50

The maximum permissible continuous power is +34 dBm due to thermal limits.