beautypg.com

Atec Rohde-Schwarz-CMW500 User Manual

Page 16

background image

Version 11.00, May 2013

16

Rohde & Schwarz R&S

®

CMW500 Wideband Radio Communication Tester

Configuration with four H570 (RF TRX) and two H590D (RF frontend (ADV.))

The three R&S

®

CMW-B570 options and R&S

®

CMW-B590D option make the four RF paths (RF path 1 RX and TX, RF path 2 RX and

TX, RF path 3 RX and TX, RF path 4 RX and TX) available on the front of the instrument at connectors RF1 COM, RF2 COM, RF1
OUT and RF3 COM, RF4 COM, RF3 OUT.

RF path 1, 2, 3 and 4 routed to separate connectors

RF generator 1 and RF generator 3

switchable to RF1 COM, RF2 COM,
RF1 OUT

see general technical specifications

RF generator 2 and RF generator 4

switchable to RF3 COM, RF4 COM,
RF3 OUT

see general technical specifications

RF analyzer 1 and RF analyzer 3

switchable to RF1 COM, RF2 COM

see general technical specifications

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value

RF analyzer 2 and RF analyzer 4

switchable to RF3 COM, RF4 COM

see general technical specifications

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value


RF path 1, RF path 3 routed to common connector and RF path 2, RF path 4 routed to common connector

RF generator 1 and RF generator 3

switchable to RF1 COM, RF2 COM,
RF1 OUT

see general technical specifications

Output level range

peak envelope power (PEP)

the specified value is valid for the total
power of the two RF generators, see
general technical specifications

Output level uncertainty

for each carrier

see general technical specifications,
+ 0.2 dB

Signal-to-noise ratio

for the carrier with the highest output level
(at least 3 dB higher than the other carrier)

see general technical specifications

RF generator 2 and RF generator 4

switchable to RF3 COM, RF4 COM,
RF3 OUT

see general technical specifications

Output level range

peak envelope power (PEP)

the specified value is valid for the total
power of the two RF generators, see
general technical specifications

Output level uncertainty

for each carrier

see general technical specifications,
+ 0.2 dB

Signal-to-noise ratio

for the carrier with the highest output level
(at least 3 dB higher than the other carrier)

see general technical specifications

RF analyzer 1 and RF analyzer 3

switchable to RF1 COM, RF2 COM

see general technical specifications

Level uncertainty

70 MHz to 3300 MHz

see general technical specifications,
+ 0.2 dB

3300 MHz to 6000 MHz

see general technical specifications,
+ 0.3 dB

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value

RF analyzer 2 and RF analyzer 4

switchable to RF3 COM, RF4 COM

see general technical specifications

Level uncertainty

70 MHz to 3300 MHz

see general technical specifications,
+ 0.2 dB

3300 MHz to 6000 MHz

see general technical specifications,
+ 0.3 dB

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value