beautypg.com

Possible configurations with two rf paths – Atec Rohde-Schwarz-CMW500 User Manual

Page 14

background image

Version 11.00, May 2013

14

Rohde & Schwarz R&S

®

CMW500 Wideband Radio Communication Tester

Possible configurations with two RF paths

6

Necessary hardware (H570, H590X):
Selections: R&S

®

CMW-S590A RF frontend (BASIC) or R&S

®

CMW-S590D RF frontend (ADV.) and R&S

®

CMW-S570 RF TRX.

Options: R&S

®

CMW-B590A RF frontend (BASIC) or R&S

®

CMW-B590D RF frontend (ADV.) and R&S

®

CMW-B570 RF TRX.

Configuration with two H570 (RF TRX) and two H590A (RF frontend (BASIC))

The R&S

®

CMW-B570 and R&S

®

CMW-B590A options make the second RF path (RF path 2) available on the front of the instrument

with three additional RF connectors, i.e. RF3 COM, RF4 COM and RF3 OUT.

RF3 COM

equivalent to RF1 COM

see general technical specifications

RF4 COM

equivalent to RF2 COM

see general technical specifications

RF3 OUT

equivalent to RF1 OUT

see general technical specifications

Configuration with two H570 (RF TRX) and one H590D (RF frontend (ADV.))

The R&S

®

CMW-B570 option and R&S

®

CMW-S590D selection make the second RF path (RF path 2) available on the front of the

instrument at connectors RF1 COM, RF2 COM and RF1 OUT.

RF path 1 and RF path 2 routed to separate connectors

RF generator 1 and RF generator 2

switchable to RF1 COM, RF2 COM,
RF1 OUT

see general technical specifications

RF analyzer 1 and RF analyzer 2

switchable to RF1 COM, RF2 COM

see general technical specifications

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value


RF path 1 and RF path 2 routed to common connector

RF generator 1 and RF generator 2

switchable to RF1 COM, RF2 COM,
RF1 OUT

see general technical specifications

Output level range

peak envelope power (PEP)

the specified value is valid for the total
power of the two RF generators, see
general technical specifications

Output level uncertainty

for each carrier

see general technical specifications,
+ 0.2 dB

Signal-to-noise ratio

for the carrier with the highest output level
(at least 3 dB higher than the other carrier)

see general technical specifications

RF analyzer 1 and RF analyzer 2

switchable to RF1 COM, RF2 COM

see general technical specifications

Level uncertainty

70 MHz to 3300 MHz

see general technical specifications,
+ 0.2 dB

3300 MHz to 6000 MHz

see general technical specifications
+ 0.3 dB

Expected nominal power setting for full
dynamic range

see general technical specifications,
+ 3 dB for lower level limit value

Level range

see general technical specifications,
+ 3 dB (typ. + 2 dB) for lower level limit
value

6

R&S

®

CMW500 and R&S

®

CMW270 only.