Cdma2000, 1xev-do specifications – access terminal test, 1xev-do rf generator (prerequisite: r&s – Atec Rohde-Schwarz-CMW500 User Manual
Page 63: Cmw-b110a/r&s, Cmw-b110d option), 1xev-do rf analyzer (r&s, Cmw-km880 option)
Version 11.00, May 2013
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 63
CDMA2000
®
1xEV-DO specifications – access terminal test
48
Standard
CDMA2000
®
1xEV-DO standards
TIA/EIA 856-2
CDMA2000
®
1xEV-DO test standards
TIA/EIA 866-A, TIA/EIA 866-B
Symbol rate
1.2288
Mcps
CDMA2000
®
1xEV-DO RF generator
(prerequisite: R&S
®
CMW-B110A/R&S
®
CMW-B110D option)
Frequency range
band class 0
860.025 MHz to 893.985 MHz
band class 1
1930.000 MHz to 1990.000 MHz
band class 2
917.0125 MHz to 959.9875 MHz
band class 3
832.0125 MHz to 869.9875 MHz
band class 4
1840.000 MHz to 1870.000 MHz
band class 5
421.675 MHz to 493.480 MHz
band class 6
2110.000 MHz to 2169.950 MHz
band class 7
746.000 MHz to 764.000 MHz
band class 8
1805.000 MHz to 1879.950 MHz
band class 9
925.000 MHz to 958.750 MHz
band class 10
851.000 MHz to 939.975 MHz
band class 11
421.675 MHz to 493.475 MHz
band class 12
915.0125 MHz to 920.9875 MHz
band class 13
2620.000 MHz to 2690 MHz
band class 14
1930.000 MHz to 1995.000 MHz
band class 15
2110.000 MHz to 2155.000 MHz
band class 16
2624.000 MHz to 2690.000 MHz
band class 17
2624.000 MHz to 2690.000 MHz
band class 18
757.000 MHz to 769.000 MHz
band class 19
728.000 MHz to 746.000 MHz
1xEV-DO WinIQSIM2™ (R&S
®
CMW-KW880 option)
Arbitrary waveform file
EVDO_DEFAULT.WV (PAR = 4.85 dB)
Output level range
depending on PAR
see general technical specifications
Output level uncertainty
waveform file used: EVDO_DEFAULT.WV see general technical specifications
Output level resolution
see general technical specifications
Signal quality
Waveform quality (rho)
waveform file used: EVDO_DEFAULT.WV > 0.99
CDMA2000
®
1xEV-DO RF analyzer (R&S
®
CMW-KM880 option)
Frequency range
band class 0
815.025 MHz to 848.985 MHz
band class 1
1850.000 MHz to 1910.000 MHz
band class 2
872.0125 MHz to 914.9875 MHz
band class 3
887.0125 MHz to 924.9875 MHz
band class 4
1750.000 MHz to 1780.000 MHz
band class 5
411.675 MHz to 483.480 MHz
band class 6
1920.000 MHz to 1979.950 MHz
band class 7
776.000 MHz to 794.000 MHz
band class 8
1710.000 MHz to 1784.950 MHz
band class 9
880.000 MHz to 913.750 MHz
band class 10
806.000 MHz to 900.975 MHz
band class 11
411.675 MHz to 483.475 MHz
band class 12
870.0125 MHz to 875.9875 MHz
band class 13
2500.000 MHz to 2570.000 MHz
band class 14
1850.000 MHz to 1915.000 MHz
band class 15
1710.000 MHz to 1755.000 MHz
band class 16
2502.000 MHz to 2568.000 MHz
band class 17
2502.000 MHz to 2567.950 MHz
band class 18
787.000 MHz to 700.000 MHz
band class 19
698.000 MHz to 716.000 MHz
48
R&S
®
CMW500 and R&S
®
CMW280 only.