Appendix a specifications, H-219x, Appendix a specifications a-1 – Xylem H-2192 User Manual
Page 57

Appendix A
Specifications
Power Requirements
Voltage Input:
9.0 to 16.0 Volts DC
Current:
900 uA (sleep, all sub systems off)
900 uA typ (standby, telephone)
25 mA typ (standby, GPRS active)
120 mA max (transmitting, GPRS)
95 mA typ (standby, radio)
Environmental
Operating Temperature:
-40E to 60E C
Operating Temperature:
-30E to 60E C (GPRS)
Storage Temperature:
-40E to 60E C
Humidity:
0 to 95% non-condensing
Mechanical
Enclosure:
Aluminum, vinyl clad
Size:
4.0" x 6.5" x 1.5" h
Mounting:
Mount bracket included
Connectors
RS-232
DB-9, female
Telephone:
RJ-11 modular jack
Power:
Phoenix Contact P/N 1757019
Alarm:
Phoenix Contact P/N 1757019
Radio
2x5 box header for ribbon cable
Antenna:
SMA, 50-ohm
USB:
USB Type B (device)
Ethernet:
10/100 Base-T
Order Information
Telephone M odem:
H-2191
GPRS M odem:
H-2192
W arranty
The W
ATER
LOG H-2191 & H-2192 are warranted against
®
defects in materials and workmanship for one year from date of
shipment.
Note
Specifications subject to change without prior notice due to on
going commitment to product testing and improvement.
LR April 6, 2010
W
ATER
LOG is a registered trademark of Design Analysis Associates, Inc.
®
Telephone Option
Features:
V.34 / 33.6Kbps + Voice
Approval:
FCC part 68
Safety:
UL 60950
GPRS Option
Type:
GPRS, quad band
Frequency:
850/900/1800/1900 MHz
Safety:
UL 60950-1
Network:
PTCRB
Voice Synthesizer
Type:
Text-to-speech, voice concatenation using
human voice samples. Pitch, volume, tone,
speed, expression, articulation, delay and
format frequency are programmable. A user
programmable dictionary allows the
pronunciation of any character to be redefined.
RF Radio Interface
Radio:
DataRadio® DL-3400 (not supplied)
Type:
Analog, synthesized telemetry link
Frequency:
132-174 MHz VHF or 380-512 MHz UHF
Power:
5-watts at 13.3V
Switched +12Vout
Internal 4.0A solid state circuit breaker
powers external radio
RS-232 Port
Type:
RS-232, DCE pinout
Baud Rate:
9600/8/N (programable)
Connector:
DB-9, female
Alarm Input Port
Type:
Switch closure
Voltage Input:
0 to 3.3V, internal 47K-ohm pullup to 3.3V
Connector:
2-pin plug-in terminal
USB Port
Type:
Type-B, device, self powered
Operation:
Supports field firmware upgrade
Ethernet Port
Type:
10/100 Base-T
LED Indicators:
speed & activity
Operation:
Send data (push) to a remote server
LED Indicators
Modem Power
:
Green
Radio Power:
Green
DSR:
Green
DCD:
Green
GPRS LINK:
Green
H-219X
Appendix A Specifications A-1