This option shows the version of the current firmware running in the unit.
Number Of Incoming Phone Calls
This status screen shows how many incoming POTS calls have came in. This counts all calls, data
and voice. In some cases it may be handy to see how many calls are coming in.
Number Of Incoming Cell Calls
This status screen shows how many incoming Cell calls have came in.
Number Of Incoming Radio Calls
This status screen shows how many incoming Radio calls have came in. This filters out unwanted
calls and only counts calls that successfully match the site ID code.
Number Of External Alarms
This status screen shows how many external alarms have happened.
B - Modem to Modem Baud Rate:
This option instructs the modem in a H-2191 to negociate a modem to modem connection at the
selected baud rate. Rate limiting is helpful at installations that have trouble connecting due to noisy
or filtered phone lines.
C - Clear Call Counters:
This option is used to set all the call and alarm counters back to zero.
V - View Data Values
This option is used to display all the values currently loaded into the modem by the data logger. This
will be up to ten different data values and each value having a current value and 12 old values. Also
each set of values will be time tagged. Below is a sample of a typical screen.
Time Box01 Box02 Box03 Box04
-------------------------------------
12:00:00 23.21 9.23 279.32 13.48
11:45:00 23.71 9.12 274.21 13.46
11:30:00 24.02 8.83 269.37 13.45
11:15:00 24.59 8.52 263.88 13.51
11:00:00 24.89 8.02 259.81 13.44
D - Wait For Data TimeOut = 20 Seconds
This option is used to set the time out to use to wait for data. If the data logger is using sensors that
take some time to measure or using long averaging times, then this needs to be adjusted.
S - Main System TimeOut = 120 Minutes
This is a system time out that will cause the system to reset if it is active for longer than a set time.
Normally no call will last longer than a few minutes but could be longer. This time must be set long
5-12 Menu Mode Reference